-
Optimal Demodulation Domain for Microwave SQUID Multiplexers in Presence of Readout System Noise
Authors:
M. E. García Redondo,
N. A. Müller,
J. M. Salum,
L. P. Ferreyro,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
T. Muscheid,
R. Gartmann,
A. Almela,
M. R. Hampel,
A. E. Fuster,
L. E. Ardila-Perez,
M. Wegner,
M. Platino,
O. Sander,
S. Kempf,
M. Weber
Abstract:
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulatio…
▽ More
The Microwave SQUID Multiplexer (μMUX) is the device of choice for the readout of a large number of Low-Temperature Detectors in a wide variety of experiments within the fields of astronomy and particle physics. While it offers large multiplexing factors, the system noise performance is highly dependent on the cold and warm-readout electronic systems used to read it out, as well as the demodulation domain and parameters chosen. In order to understand the impact of the readout systems in the overall detection system noise performance, first we extended the available μMUX simulation frameworks including additive and multiplicative noise sources in the probing tones (i.e. phase and amplitude noise), along with the capability of demodulating the scientific data, either in resonator's phase or scattering amplitude. Then, considering the additive noise as a dominant noise source, the optimum readout parameters to achieve minimum system noise were found for both open-loop and flux-ramp demodulation schemes in the aforementioned domains. Later, we evaluated the system noise sensitivity to multiplicative noise sources under the optimum readout parameters. Finally, as a case study, we evaluated the optimal demodulation domain and expected system noise level for a typical Software-Defined Radio (SDR) readout system. This work leads to an improved system performance prediction and noise engineering based on the available readout electronics and selected demodulation domain.
△ Less
Submitted 19 August, 2024; v1 submitted 10 June, 2024;
originally announced June 2024.
-
RFSoC Gen3-Based Software-Defined Radio Characterization for the Readout System of Low-Temperature Bolometers
Authors:
M. E. García Redondo,
T. Muscheid,
R. Gartmann,
J. M. Salum,
L. P. Ferreyro,
N. A. Müller,
J. D. Bonilla-Neira,
J. M. Geria,
J. J. Bonaparte,
A. Almela,
L. E. Ardila-Perez,
M. R. Hampel,
A. E. Fuster,
M. Platino,
O. Sander,
M. Weber,
A. Etchegoyen
Abstract:
This work reports the performance evaluation of an SDR readout system based on the latest generation (Gen3) of the AMD's Radio Frequency System-on-Chip (RFSoC) processing platform, which integrates a full-stack processing system and a powerful FPGA with up to 32 high-speed and high-resolution 14-bit Digital-to-Analog Converters (DACs) and Analog-to-Digital Converters (ADCs). The proposed readout s…
▽ More
This work reports the performance evaluation of an SDR readout system based on the latest generation (Gen3) of the AMD's Radio Frequency System-on-Chip (RFSoC) processing platform, which integrates a full-stack processing system and a powerful FPGA with up to 32 high-speed and high-resolution 14-bit Digital-to-Analog Converters (DACs) and Analog-to-Digital Converters (ADCs). The proposed readout system uses a previously developed multi-band, double-conversion IQ RF-mixing board targeting a multiplexing factor of approximately 1,000 bolometers in a bandwidth between 4 and 8 GHz, in line with state-of-the-art microwave SQUID multiplexers ($μ$MUX). The characterization of the system was performed in two stages, under the conditions typically imposed by the multiplexer and the cold readout circuit. First, in transmission, showing that noise and spurious levels of the generated tones are close to the values imposed by the cold readout. Second, in RF loopback, presenting noise values better than -100 dBc/Hz totally in agreement with the state-of-the-art readout systems. It was demonstrated that the RFSoC Gen3 device is a suitable enabling technology for the next generation of superconducting detector readout systems, reducing system complexity, increasing system integration, and achieving these goals without performance degradation.
△ Less
Submitted 8 May, 2024; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Measuring the CMB primordial B-modes with Bolometric Interferometry
Authors:
A. Mennella,
P. Ade,
A. Almela,
G. Amico,
L. H. Arnaldi,
J. Aumont,
S. Banfi,
E. S. Battistelli,
B. Bélier,
L. Bergé,
J. -Ph. Bernard,
P. de Bernardis,
M. Bersanelli,
J. Bonaparte,
J. D. Bonilla,
E. Bunn,
D. Buzi,
F. Cacciotti,
D. Camilieri,
F. Cavaliere,
P. Chanial,
C. Chapron,
L. Colombo,
F. Columbro,
A. Coppolecchia
, et al. (89 additional authors not shown)
Abstract:
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest fo…
▽ More
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of Δν/ν \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.
△ Less
Submitted 5 November, 2023;
originally announced November 2023.
-
An Implementation of a Channelizer based on a Goertzel Filter Bank for the Read-Out of Cryogenic Sensors
Authors:
L. P. Ferreyro,
M. García Redondo,
M. R. Hampel,
A. Almela,
A. Fuster,
J. Salum,
J. M. Geria,
J. Bonaparte,
J. Bonilla-Neira,
N. Müller,
N. Karcher,
O. Sander,
M. Platino,
A. Etchegoyen
Abstract:
In this work we present an application of the Goertzel Filter for the channelization of multi-tonal signals, typically used for the read-out of cryogenic sensors which are multiplexed in the frequency domain (FDM), by means of Microwave Superconducting Quantum Interference Device (SQUID) Multiplexer ($μ$MUX). We demonstrate how implementing a bank of many of these filters, can be used to perform a…
▽ More
In this work we present an application of the Goertzel Filter for the channelization of multi-tonal signals, typically used for the read-out of cryogenic sensors which are multiplexed in the frequency domain (FDM), by means of Microwave Superconducting Quantum Interference Device (SQUID) Multiplexer ($μ$MUX). We demonstrate how implementing a bank of many of these filters, can be used to perform a channelization of the multi-tonal input signal to retrieve the data added by the sensors. We show how this approach can be implemented in a resource-efficient manner in a Field Programmable Gate Array (FPGA) within the state-of-the-art, which allows great scalability for reading thousands of sensors; as is required by Radio Telescopes in Cosmic Microwave Background Radiation (CMB) surveys using cryogenic bolometers, particles detection like Neutrino mass estimation using cryogenic calorimeters or Quantum Computing.
△ Less
Submitted 2 March, 2023;
originally announced March 2023.
-
Status of QUBIC, the Q&U Bolometer for Cosmology
Authors:
L. Mousset,
P. Ade,
A. Almela,
G. Amico,
L. H. Arnaldi,
J. Aumont,
S. Banfi,
E. S. Battistelli,
B. Bélier,
L. Bergé,
J. -Ph. Bernard,
P. de Bernardis,
M. Bersanelli,
J. Bonaparte,
J. D. Bonilla,
E. Bunn,
D. Buzi,
D. Camilieri,
F. Cavaliere,
P. Chanial,
C. Chapron,
S. Colombo,
F. Columbro,
A. Coppolecchia,
B. Costanza
, et al. (86 additional authors not shown)
Abstract:
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregr…
▽ More
The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematics with those of bolometric detectors in terms of wide-band, background-limited sensitivity.
△ Less
Submitted 6 October, 2022;
originally announced October 2022.
-
Suitability of Magnetic Microbolometers based on Paramagnetic Temperature Sensors for CMB Polarization Measurements
Authors:
Juan Manuel Geria,
Matias Rolf Hampel,
Sebastian Kempf,
Juan Jose Bonaparte,
Luciano Pablo Ferreyro,
Manuel Elías García Redondo,
Daniel Alejandro Almela,
Juan Manuel Salum,
Nahuel Müller,
Jesus David Bonilla-Neira,
Alan Ezequiel Fuster,
Manuel Platino,
Alberto Etchegoyen
Abstract:
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detector…
▽ More
High resolution maps of polarization anisotropies of the Cosmic Microwave Background (CMB) are in high demand, since the discovery of primordial B-Modes in the polarization patterns would confirm the inflationary phase of the Universe that would have taken place before the last scattering of the CMB at the recombination epoch. Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) are the predominant detector technologies of cryogenic detector array based CMB instruments that search for primordial B-Modes. In this paper we propose another type of cryogenic detector to be used for CMB survey: A magnetic microbolometer (MMB) that is based on a paramagnetic temperature sensor. It is an adaption of state-of-the-art metallic magnetic calorimeters (MMCs) that are meanwhile a key technology for high resolution $α$, $β$, $γ$ and X-ray spectroscopy as well as the study of neutrino mass. The effort to adapt MMCs for CMB surveys is triggered by their lack of Johnson noise associated with the detector readout, the possibility of straightforward calibration and higher dynamic range given it possesses a broad and smooth responsivity dependence with temperature and the absence of Joule dissipation which simplifies the thermal design. A brief proof of concept case study is analyzed, taking into account typical constraints in CMB measurements and reliable microfabrication processes. The results show that MMBs provide a promising technology for CMB polarization survey as their sensitivity can be tuned for background limited detection of the sky while simultaneously maintaining a low time response to avoid distortion of the point-source response of the telescope. As the sensor technology and its fabrication techniques are compatible with TES based bolometric detector arrays, a change of detector technology would even come with very low cost.
△ Less
Submitted 10 June, 2024; v1 submitted 13 September, 2022;
originally announced September 2022.
-
QUBIC IV: Performance of TES Bolometers and Readout Electronics
Authors:
M. Piat,
G. Stankowiak,
E. S. Battistelli,
P. de Bernardis,
G. D Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
T. D. Hoang,
S. Marnieros,
S. Masi,
A. Mennella,
L. Mousset,
C. O Sullivan,
D. Prele,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi
, et al. (104 additional authors not shown)
Abstract:
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are…
▽ More
A prototype version of the Q & U bolometric interferometer for cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology laboratory in Paris (APC). The detection chain is currently made of 256 NbSi transition edge sensors (TES) cooled to 320 mK. The readout system is a 128:1 time domain multiplexing scheme based on 128 SQUIDs cooled at 1 K that are controlled and amplified by an SiGe application specific integrated circuit at 40 K. We report the performance of this readout chain and the characterization of the TES. The readout system has been functionally tested and characterized in the lab and in QUBIC. The low noise amplifier demonstrated a white noise level of 0.3 nV.Hz^-0.5. Characterizations of the QUBIC detectors and readout electronics includes the measurement of I-V curves, time constant and the noise equivalent power. The QUBIC TES bolometer array has approximately 80% detectors within operational parameters. It demonstrated a thermal decoupling compatible with a phonon noise of about 5.10^-17 W.Hz^-0.5 at 410 mK critical temperature. While still limited by microphonics from the pulse tubes and noise aliasing from readout system, the instrument noise equivalent power is about 2.10^-16 W.Hz^-0.5, enough for the demonstration of bolometric interferometry.
△ Less
Submitted 20 October, 2021; v1 submitted 17 January, 2021;
originally announced January 2021.
-
QUBIC I: Overview and ScienceProgram
Authors:
J. -Ch. Hamilton,
L. Mousset,
E. S. Battistelli,
M. -A. Bigot-Sazy,
P. Chanial,
R. Charlassier,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
M. M. Gamboa Lerena,
L. Grandsire,
S. Lau,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
M. Piat,
G. Riccardi,
C. Scóccola,
M. Stolpovskiy,
A. Tartari,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade
, et al. (105 additional authors not shown)
Abstract:
The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical fo…
▽ More
The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.
△ Less
Submitted 26 August, 2021; v1 submitted 4 November, 2020;
originally announced November 2020.
-
QUBIC II: Spectro-Polarimetry with Bolometric Interferometry
Authors:
L. Mousset,
M. M. Gamboa Lerena,
E. S. Battistelli,
P. de Bernardis,
P. Chanial,
G. D'Alessandro,
G. Dashyan,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
F. Incardona,
S. Landau,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
M. Piat,
G. Ricciardi,
C. G. Scóccola,
M. Stolpovskiy,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (106 additional authors not shown)
Abstract:
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foreg…
▽ More
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.
△ Less
Submitted 28 March, 2022; v1 submitted 28 October, 2020;
originally announced October 2020.
-
QUBIC VII: The feedhorn-switch system of the technological demonstrator
Authors:
F. Cavaliere,
A. Mennella,
M. Zannoni,
P. Battaglia,
E. S. Battistelli,
D. Burke,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
C. Franceschet,
L. Grandsire,
J. -Ch. Hamilton,
B. Maffei,
E. Manzan,
S. Marnieros,
S. Masi,
C. O'Sullivan,
A. Passerini,
F. Pezzotta,
M. Piat,
A. Tartari,
S. A. Torchinsky,
D. Viganò,
F. Voisin,
P. Ade
, et al. (106 additional authors not shown)
Abstract:
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration…
▽ More
We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.
△ Less
Submitted 1 April, 2022; v1 submitted 28 August, 2020;
originally announced August 2020.
-
QUBIC VI: cryogenic half wave plate rotator, design and performances
Authors:
G. D'Alessandro,
L. Mele,
F. Columbro,
G. Amico,
E. S. Battistelli,
P. de Bernardis,
A. Coppolecchia,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
L. Lamagna,
S. Marnieros,
S. Masi,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
G. Pisano,
G. Presta,
A. Tartari,
S. A. Torchinsky,
F. Voisin,
M. Zannoni,
P. Ade
, et al. (104 additional authors not shown)
Abstract:
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used t…
▽ More
Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).
△ Less
Submitted 19 November, 2020; v1 submitted 24 August, 2020;
originally announced August 2020.
-
QUBIC V: Cryogenic system design and performance
Authors:
S. Masi,
E. S. Battistelli,
P. de Bernardis,
C. Chapron,
F. Columbro,
G. D'Alessandro,
M. De Petris,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
L. Mele,
A. May,
A. Mennella,
C. O'Sullivan,
A. Paiella,
F. Piacentini,
M. Piat,
L. Piccirillo,
G. Presta,
A. Schillaci,
A. Tartari,
J. -P. Thermeau,
S. A. Torchinsky,
F. Voisin,
M. Zannoni
, et al. (104 additional authors not shown)
Abstract:
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interfe…
▽ More
Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.
△ Less
Submitted 25 August, 2021; v1 submitted 24 August, 2020;
originally announced August 2020.
-
QUBIC VIII: Optical design and performance
Authors:
C. O'Sullivan,
M. De Petris,
G. Amico,
E. S. Battistelli,
D. Burke,
D. Buzi,
C. Chapron,
L. Conversi,
G. D'Alessandro,
P. de Bernardis,
M. De Leo,
D. Gayer,
L. Grandsire,
J. -Ch. Hamilton,
S. Marnieros,
S. Masi,
A. Mattei,
A. Mennella,
L. Mousset,
J. D. Murphy,
A. Pelosi,
M. Perciballi,
M. Piat,
S. Scully,
A. Tartari
, et al. (104 additional authors not shown)
Abstract:
The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or p…
▽ More
The Q and U Bolometric Interferometer for Cosmology (QUBIC) is a ground-based experiment that aims to detect B-mode polarisation anisotropies in the CMB at angular scales around the l=100 recombination peak. Systematic errors make ground-based observations of B modes at millimetre wavelengths very challenging and QUBIC mitigates these problems in a somewhat complementary way to other existing or planned experiments using the novel technique of bolometric interferometry. This technique takes advantage of the sensitivity of an imager and the systematic error control of an interferometer. A cold reflective optical combiner superimposes there-emitted beams from 400 aperture feedhorns on two focal planes. A shielding system composedof a fixed groundshield, and a forebaffle that moves with the instrument, limits the impact of local contaminants. The modelling, design, manufacturing and preliminary measurements of the optical components are described in this paper.
△ Less
Submitted 25 August, 2021; v1 submitted 23 August, 2020;
originally announced August 2020.
-
QUBIC III: Laboratory Characterization
Authors:
S. A. Torchinsky,
J. -Ch. Hamilton,
M. Piat,
E. S. Battistelli,
C. Chapron,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
M. M. Gamboa Lerena,
M. González,
L. Grandsire,
S. Masi,
S. Marnieros,
A. Mennella,
L. Mousset,
J. D. Murphy,
D. Prêle,
G. Stankowiak,
C. O'Sullivan,
A. Tartari,
J. -P. Thermeau,
F. Voisin,
M. Zannoni,
P. Ade,
J. G. Alberro
, et al. (103 additional authors not shown)
Abstract:
A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam,…
▽ More
A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.
△ Less
Submitted 15 March, 2022; v1 submitted 23 August, 2020;
originally announced August 2020.
-
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Authors:
E. S. Battistelli,
P. Ade,
J. G. Alberro,
A. Almela,
G. Amico,
L. H. Arnaldi,
D. Auguste,
J. Aumont,
S. Azzoni,
S. Banfi,
P. Battaglia,
A. Baù,
B. Bèlier,
D. Bennett,
L. Bergè,
J. -Ph. Bernard,
M. Bersanelli,
M. -A. Bigot-Sazy,
N. Bleurvacq,
J. Bonaparte,
J. Bonis,
A. Bottani,
E. Bunn,
D. Burke,
D. Buzi
, et al. (114 additional authors not shown)
Abstract:
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addr…
▽ More
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative experiment designed to measure the polarization of the Cosmic Microwave Background and in particular the signature left therein by the inflationary expansion of the Universe. The expected signal is extremely faint, thus extreme sensitivity and systematic control are necessary in order to attempt this measurement. QUBIC addresses these requirements using an innovative approach combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with the deep control of systematics characteristic of interferometers. This makes QUBIC unique with respect to others classical imagers experiments devoted to the CMB polarization. In this contribution we report a description of the QUBIC instrument including recent achievements and the demonstration of the bolometric interferometry performed in lab. QUBIC will be deployed at the observation site in Alto Chorrillos, in Argentina at the end of 2019.
△ Less
Submitted 28 January, 2020;
originally announced January 2020.
-
QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB
Authors:
M. Piat,
B. Bélier,
L. Bergé,
N. Bleurvacq,
C. Chapron,
S. Dheilly,
L. Dumoulin,
M. González,
L. Grandsire,
J. -Ch. Hamilton,
S. Henrot-Versillé,
D. T. Hoang,
S. Marnieros,
W. Marty,
L. Montier,
E. Olivieri,
C. Oriol,
C. Perbost,
D. Prêle,
D. Rambaud,
M. Salatino,
G. Stankowiak,
J. -P. Thermeau,
S. Torchinsky,
F. Voisin
, et al. (113 additional authors not shown)
Abstract:
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detec…
▽ More
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.
△ Less
Submitted 9 December, 2019; v1 submitted 27 November, 2019;
originally announced November 2019.
-
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric Interferometer
Authors:
Aniello Mennella,
Peter Ade,
Giorgio Amico,
Didier Auguste,
Jonathan Aumont,
Stefano Banfi,
Gustavo Barbaràn,
Paola Battaglia,
Elia Battistelli,
Alessandro Baù,
Benoit Bélier,
David G. Bennett,
Laurent Bergé,
Jean Philippe Bernard,
Marco Bersanelli,
Marie Anne Bigot Sazy,
Nathat Bleurvacq,
Juan Bonaparte,
Julien Bonis,
Emory F. Bunn,
David Burke,
Daniele Buzi,
Alessandro Buzzelli,
Francesco Cavaliere,
Pierre Chanial
, et al. (105 additional authors not shown)
Abstract:
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its…
▽ More
In this paper we describe QUBIC, an experiment that will observe the polarized microwave sky with a novel approach, which combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. QUBIC unique features are the so-called "self-calibration", a technique that allows us to clean the measured data from instrumental effects, and its spectral imaging power, i.e. the ability to separate the signal in various sub-bands within each frequency band. QUBIC will observe the sky in two main frequency bands: 150 GHz and 220 GHz. A technological demonstrator is currently under testing and will be deployed in Argentina during 2019, while the final instrument is expected to be installed during 2020.
△ Less
Submitted 23 January, 2019; v1 submitted 30 November, 2018;
originally announced December 2018.
-
Thermal architecture for the QUBIC cryogenic receiver
Authors:
A. J. May,
C. Chapron,
G. Coppi,
G. D'Alessandro,
P. de Bernardis,
S. Masi,
S. Melhuish,
M. Piat,
L. Piccirillo,
A. Schillaci,
J. -P. Thermeau,
P. Ade,
G. Amico,
D. Auguste,
J. Aumont,
S. Banfi,
G. Barbara,
P. Battaglia,
E. Battistelli,
A. Bau,
B. Belier,
D. Bennett,
L. Berge,
J. -Ph. Bernard,
M. Bersanelli
, et al. (105 additional authors not shown)
Abstract:
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex opt…
▽ More
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
△ Less
Submitted 6 November, 2018;
originally announced November 2018.