-
A chemically etched corrugated feedhorn array for D-band CMB observations
Authors:
Stefano Mandelli,
Elenia Manzan,
Aniello Mennella,
Francesco Cavaliere,
Daniele Viganò,
Cristian Franceschet,
Paolo de Bernardis,
Marco Bersanelli,
Maria Gabriella Castellano,
Alessandro Coppolecchia,
Angelo Cruciani,
Massimo Gervasi,
Luca Lamagna,
Andrea Limonta,
Silvia Masi,
Alessandro Paiella,
Andrea Passerini,
Giorgio Pettinari,
Francesco Piacentini,
Elisabetta Tommasi,
Angela Volpe,
Mario Zannoni
Abstract:
We present the design, manufacturing, and testing of a 37-element array of corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between $140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance Detector arrays, either directly (for total power measurements) or through an orthomode transducer (for polarization measurements). We manufactured the array in plat…
▽ More
We present the design, manufacturing, and testing of a 37-element array of corrugated feedhorns for Cosmic Microwave Background (CMB) measurements between $140$ and $170$ GHz. The array was designed to be coupled to Kinetic Inductance Detector arrays, either directly (for total power measurements) or through an orthomode transducer (for polarization measurements). We manufactured the array in platelets by chemically etching aluminum plates of $0.3$ mm and $0.4$ mm thickness. The process is fast, low-cost, scalable, and yields high-performance antennas compared to other techniques in the same frequency range. Room temperature electromagnetic measurements show excellent repeatability with an average cross polarization level about $-20$ dB, return loss about $-25$ dB, first sidelobes below $-25$ dB and far sidelobes below $-35$ dB. Our results qualify this process as a valid candidate for state-of-the-art CMB experiments, where large detector arrays with high sensitivity and polarization purity are of paramount importance in the quest for the discovery of CMB polarization $B$-modes.
△ Less
Submitted 21 October, 2020; v1 submitted 26 June, 2020;
originally announced June 2020.
-
In-flight performance of the LEKIDs of the OLIMPO experiment
Authors:
A. Paiella,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
M. De Petris,
S. Gordon,
L. Lamagna,
C. Magneville,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Pisano,
G. Polenta,
G. Presta,
E. Tommasi,
C. Tucker,
V. Vdovin,
A. Volpe,
D. Yvon
Abstract:
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the firs…
▽ More
We describe the in-flight performance of the horn-coupled Lumped Element Kinetic Inductance Detector arrays of the balloon-borne OLIMPO experiment. These arrays have been designed to match the spectral bands of OLIMPO: 150, 250, 350, and 460 GHz, and they have been operated at 0.3 K and at an altitude of 37.8 km during the stratospheric flight of the OLIMPO payload, in Summer 2018. During the first hours of flight, we tuned the detectors and verified their large dynamics under the radiative background variations due to elevation increase of the telescope and to the insertion of the plug-in room-temperature differential Fourier transform spectrometer into the optical chain. We have found that the detector noise equivalent powers are close to be photon-noise limited and lower than those measured on the ground. Moreover, the data contamination due to primary cosmic rays hitting the arrays is less than 3% for all the pixels of all the arrays, and less than 1% for most of the pixels. These results can be considered the first step of KID technology validation in a representative space environment.
△ Less
Submitted 10 February, 2020;
originally announced February 2020.
-
Kinetic Inductance Detectors and readout electronics for the OLIMPO experiment
Authors:
A. Paiella,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
A. Coppolecchia,
G. D'Alessandro,
P. de Bernardis,
S. Gordon,
L. Lamagna,
H. Mani,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Presta
Abstract:
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is ai…
▽ More
Kinetic Inductance Detectors (KIDs) are superconductive low$-$temperature detectors useful for astrophysics and particle physics. We have developed arrays of lumped elements KIDs (LEKIDs) sensitive to microwave photons, optimized for the four horn-coupled focal planes of the OLIMPO balloon-borne telescope, working in the spectral bands centered at 150 GHz, 250 GHz, 350 GHz, and 460 GHz. This is aimed at measuring the spectrum of the Sunyaev-Zel'dovich effect for a number of galaxy clusters, and will validate LEKIDs technology in a space-like environment. Our detectors are optimized for an intermediate background level, due to the presence of residual atmosphere and room--temperature optical system and they operate at a temperature of 0.3 K. The LEKID planar superconducting circuits are designed to resonate between 100 and 600 MHz, and to match the impedance of the feeding waveguides; the measured quality factors of the resonators are in the $10^{4}-10^{5}$ range, and they have been tuned to obtain the needed dynamic range. The readout electronics is composed of a $cold$ $part$, which includes a low noise amplifier, a dc$-$block, coaxial cables, and power attenuators; and a $room-temperature$ $part$, FPGA$-$based, including up and down-conversion microwave components (IQ modulator, IQ demodulator, amplifiers, bias tees, attenuators). In this contribution, we describe the optimization, fabrication, characterization and validation of the OLIMPO detector system.
△ Less
Submitted 3 April, 2019;
originally announced April 2019.
-
Kinetic Inductance Detectors for the OLIMPO experiment: in--flight operation and performance
Authors:
S. Masi,
P. de Bernardis,
A. Paiella,
F. Piacentini,
L. Lamagna,
A. Coppolecchia,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
G. D'Alessandro,
M. De Petris,
S. Gordon,
C. Magneville,
P. Mauskopf,
G. Pettinari,
G. Pisano,
G. Polenta,
G. Presta,
E. Tommasi,
C. Tucker,
V. Vdovin,
A. Volpe,
D. Yvon
Abstract:
We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the detectors can be tuned in-flight, and their performance is robust against radiative background changes due to varying telescope elevation. We also find that the n…
▽ More
We report on the performance of lumped--elements Kinetic Inductance Detector (KID) arrays for mm and sub--mm wavelengths, operated at 0.3K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the detectors can be tuned in-flight, and their performance is robust against radiative background changes due to varying telescope elevation. We also find that the noise equivalent power of the detectors in flight is significantly reduced with respect to the one measured in the laboratory, and close to photon-noise limited performance. The effect of primary cosmic rays crossing the detector is found to be consistent with the expected ionization energy loss with phonon-mediated energy transfer from the ionization sites to the resonators. In the OLIMPO detector arrays, at float, cosmic ray events affect less than 4% of the detector samplings for all the pixels of all the arrays, and less than 1% of the samplings for most of the pixels. These results are also representative of what one can expect from primary cosmic rays in a satellite mission with similar KIDs and instrument environment.
△ Less
Submitted 24 February, 2019;
originally announced February 2019.
-
Kinetic Inductance Detectors for the OLIMPO experiment: design and pre-flight characterization
Authors:
A. Paiella,
A. Coppolecchia,
L. Lamagna,
P. A. R. Ade,
E. S. Battistelli,
M. G. Castellano,
I. Colantoni,
F. Columbro,
G. D'Alessandro,
P. de Bernardis,
S. Gordon,
S. Masi,
P. Mauskopf,
G. Pettinari,
F. Piacentini,
G. Pisano,
G. Presta,
C. Tucker
Abstract:
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environ…
▽ More
We designed, fabricated, and characterized four arrays of horn--coupled, lumped element kinetic inductance detectors (LEKIDs), optimized to work in the spectral bands of the balloon-borne OLIMPO experiment. OLIMPO is a 2.6 m aperture telescope, aimed at spectroscopic measurements of the Sunyaev-Zel'dovich (SZ) effect. OLIMPO will also validate the LEKID technology in a representative space environment. The corrected focal plane is filled with diffraction limited horn-coupled KID arrays, with 19, 37, 23, 41 active pixels respectively at 150, 250, 350, and 460$\:$GHz. Here we report on the full electrical and optical characterization performed on these detector arrays before the flight. In a dark laboratory cryostat, we measured the resonator electrical parameters, such as the quality factors and the electrical responsivities, at a base temperature of 300$\:$mK. The measured average resonator $Q$s are 1.7$\times{10^4}$, 7.0$\times{10^4}$, 1.0$\times{10^4}$, and 1.0$\times{10^4}$ for the 150, 250, 350, and 460$\:$GHz arrays, respectively. The average electrical phase responsivities on resonance are 1.4$\:$rad/pW, 1.5$\:$rad/pW, 2.1$\:$rad/pW, and 2.1$\:$rad/pW; the electrical noise equivalent powers are 45$\:\rm{aW/\sqrt{Hz}}$, 160$\:\rm{aW/\sqrt{Hz}}$, 80$\:\rm{aW/\sqrt{Hz}}$, and 140$\:\rm{aW/\sqrt{Hz}}$, at 12 Hz. In the OLIMPO cryostat, we measured the optical properties, such as the noise equivalent temperatures (NET) and the spectral responses. The measured NET$_{\rm RJ}$s are $200\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, $240\:μ\rm{K\sqrt{s}}$, and $\:340μ\rm{K\sqrt{s}}$, at 12 Hz; under 78, 88, 92, and 90 mK Rayleigh-Jeans blackbody load changes respectively for the 150, 250, 350, and 460 GHz arrays. The spectral responses were characterized with the OLIMPO differential Fourier transform spectrometer (DFTS) up to THz frequencies, with a resolution of 1.8 GHz.
△ Less
Submitted 3 April, 2019; v1 submitted 1 October, 2018;
originally announced October 2018.
-
Ultra High Molecular Weight Polyethylene: optical features at millimeter wavelengths
Authors:
G. D'Alessandro,
A. Paiella,
A. Coppolecchia,
M. G. Castellano,
I. Colantoni,
P. de Bernardis,
L. Lamagna,
S. Masi
Abstract:
The next generation of experiments for the measurement of the Cosmic Microwave Background (CMB) requires more and more the use of advanced materials, with specific physical and structural properties. An example is the material used for receiver's cryostat windows and internal lenses. The large throughput of current CMB experiments requires a large diameter (of the order of 0.5m) of these parts, re…
▽ More
The next generation of experiments for the measurement of the Cosmic Microwave Background (CMB) requires more and more the use of advanced materials, with specific physical and structural properties. An example is the material used for receiver's cryostat windows and internal lenses. The large throughput of current CMB experiments requires a large diameter (of the order of 0.5m) of these parts, resulting in heavy structural and optical requirements on the material to be used. Ultra High Molecular Weight (UHMW) polyethylene (PE) features high resistance to traction and good transmissivity in the frequency range of interest. In this paper, we discuss the possibility of using UHMW PE for windows and lenses in experiments working at millimeter wavelengths, by measuring its optical properties: emissivity, transmission and refraction index. Our measurements show that the material is well suited to this purpose.
△ Less
Submitted 14 March, 2018;
originally announced March 2018.
-
Exploring Cosmic Origins with CORE: Cluster Science
Authors:
J. -B. Melin,
A. Bonaldi,
M. Remazeilles,
S. Hagstotz,
J. M. Diego,
C. Hernández-Monteagudo,
R. T. Génova-Santos,
G. Luzzi,
C. J. A. P. Martins,
S. Grandis,
J. J. Mohr,
J. G. Bartlett,
J. Delabrouille,
S. Ferraro,
D. Tramonte,
J. A. Rubiño-Martín,
J. F. Macìas-Pérez,
A. Achúcarro,
P. Ade,
R. Allison,
M. Ashdown,
M. Ballardini,
A. J. Banday,
R. Banerji,
N. Bartolo
, et al. (96 additional authors not shown)
Abstract:
We examine the cosmological constraints that can be achieved with a galaxy cluster survey with the future CORE space mission. Using realistic simulations of the millimeter sky, produced with the latest version of the Planck Sky Model, we characterize the CORE cluster catalogues as a function of the main mission performance parameters. We pay particular attention to telescope size, key to improved…
▽ More
We examine the cosmological constraints that can be achieved with a galaxy cluster survey with the future CORE space mission. Using realistic simulations of the millimeter sky, produced with the latest version of the Planck Sky Model, we characterize the CORE cluster catalogues as a function of the main mission performance parameters. We pay particular attention to telescope size, key to improved angular resolution, and discuss the comparison and the complementarity of CORE with ambitious future ground-based CMB experiments that could be deployed in the next decade. A possible CORE mission concept with a 150 cm diameter primary mirror can detect of the order of 50,000 clusters through the thermal Sunyaev-Zeldovich effect (SZE). The total yield increases (decreases) by 25% when increasing (decreasing) the mirror diameter by 30 cm. The 150 cm telescope configuration will detect the most massive clusters ($>10^{14}\, M_\odot$) at redshift $z>1.5$ over the whole sky, although the exact number above this redshift is tied to the uncertain evolution of the cluster SZE flux-mass relation; assuming self-similar evolution, CORE will detect $\sim 500$ clusters at redshift $z>1.5$. This changes to 800 (200) when increasing (decreasing) the mirror size by 30 cm. CORE will be able to measure individual cluster halo masses through lensing of the cosmic microwave background anisotropies with a 1-$σ$ sensitivity of $4\times10^{14} M_\odot$, for a 120 cm aperture telescope, and $10^{14} M_\odot$ for a 180 cm one. [abridged]
△ Less
Submitted 30 March, 2017;
originally announced March 2017.
-
Exploring Cosmic Origins with CORE: Extragalactic sources in Cosmic Microwave Background maps
Authors:
G. De Zotti,
J. Gonzalez-Nuevo,
M. Lopez-Caniego,
M. Negrello,
J. Greenslade,
C. Hernandez-Monteagudo,
J. Delabrouille,
Z. -Y. Cai,
M. Bonato,
A. Achucarro,
P. Ade,
R. Allison,
M. Ashdown,
M. Ballardini,
A. J. Banday,
R. Banerji,
J. G. Bartlett,
N. Bartolo,
S. Basak,
M. Bersanelli,
M. Biesiada,
M. Bilicki,
A. Bonaldi,
J. Borrill,
F. Bouchet
, et al. (99 additional authors not shown)
Abstract:
We discuss the potential of a next generation space-borne Cosmic Microwave Background (CMB) experiment for studies of extragalactic sources. Our analysis has particular bearing on the definition of the future space project, CORE, that has been submitted in response to ESA's call for a Medium-size mission opportunity as the successor of the Planck satellite. Even though the effective telescope size…
▽ More
We discuss the potential of a next generation space-borne Cosmic Microwave Background (CMB) experiment for studies of extragalactic sources. Our analysis has particular bearing on the definition of the future space project, CORE, that has been submitted in response to ESA's call for a Medium-size mission opportunity as the successor of the Planck satellite. Even though the effective telescope size will be somewhat smaller than that of Planck, CORE will have a considerably better angular resolution at its highest frequencies, since, in contrast with Planck, it will be diffraction limited at all frequencies. The improved resolution implies a considerable decrease of the source confusion, i.e. substantially fainter detection limits. In particular, CORE will detect thousands of strongly lensed high-z galaxies distributed over the full sky. The extreme brightness of these galaxies will make it possible to study them, via follow-up observations, in extraordinary detail. Also, the CORE resolution matches the typical sizes of high-z galaxy proto-clusters much better than the Planck resolution, resulting in a much higher detection efficiency; these objects will be caught in an evolutionary phase beyond the reach of surveys in other wavebands. Furthermore, CORE will provide unique information on the evolution of the star formation in virialized groups and clusters of galaxies up to the highest possible redshifts. Finally, thanks to its very high sensitivity, CORE will detect the polarized emission of thousands of radio sources and, for the first time, of dusty galaxies, at mm and sub-mm wavelengths, respectively.
△ Less
Submitted 18 May, 2017; v1 submitted 23 September, 2016;
originally announced September 2016.
-
High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out
Authors:
F. Bellini,
L. Cardani,
N. Casali,
M. G. Castellano,
I. Colantoni,
C. Cosmelli,
A. Cruciani,
A. D'Addabbo,
S. Di Domizio,
M. Martinez,
C. Tomei,
M. Vignati
Abstract:
The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed K…
▽ More
The development of wide-area cryogenic light detectors with good energy resolution is one of the priorities of next generation bolometric experiments searching for rare interactions, as the simultaneous read-out of the light and heat signals enables background suppression through particle identification. Among the proposed technological approaches for the phonon sensor, the naturally-multiplexed Kinetic Inductance Detectors (KIDs) stand out for their excellent intrinsic energy resolution and reproducibility. To satisfy the large surface requirement (several cm$^2$) KIDs are deposited on an insulating substrate that converts the impinging photons into phonons. A fraction of phonons is absorbed by the KID, producing a signal proportional to the energy of the original photons. The potential of this technique was proved by the CALDER project, that reached a baseline resolution of 154$\pm$7 eV RMS by sampling a 2$\times$2 cm$^2$ Silicon substrate with 4 Aluminum KIDs. In this paper we present a prototype of Aluminum KID with improved geometry and quality factor. The design improvement, as well as the combined analysis of amplitude and phase signals, allowed to reach a baseline resolution of 82$\pm$4 eV by sampling the same substrate with a single Aluminum KID.
△ Less
Submitted 14 December, 2016; v1 submitted 14 June, 2016;
originally announced June 2016.
-
Development of Lumped Element Kinetic Inductance Detectors for the W-Band
Authors:
A. Paiella,
A. Coppolecchia,
M. G. Castellano,
I. Colantoni,
A. Cruciani,
A. D'Addabbo,
P. de Bernardis,
S. Masi,
G. Presta
Abstract:
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is close to optimal in terms of contamination of the CMB from Galactic synchrotron, free-free, and thermal interstellar dust. In this band, the atmosphere has very…
▽ More
We are developing a Lumped Element Kinetic Inductance Detector (LEKID) array able to operate in the W-band (75-110 GHz) in order to perform ground-based Cosmic Microwave Background (CMB) and mm-wave astronomical observations. The W-band is close to optimal in terms of contamination of the CMB from Galactic synchrotron, free-free, and thermal interstellar dust. In this band, the atmosphere has very good transparency, allowing interesting ground-based observations with large (>30 m) telescopes, achieving high angular resolution (<0.4 arcmin). In this work we describe the startup measurements devoted to the optimization of a W-band camera/spectrometer prototype for large aperture telescopes like the 64 m SRT (Sardinia Radio Telescope). In the process of selecting the best superconducting film for the LEKID, we characterized a 40 nm thick Aluminum 2-pixel array. We measured the minimum frequency able to break CPs (i.e. $hν=2Δ\left(T_{c}\right)=3.5k_{B}T_{c}$) obtaining $ν=95.5$ GHz, that corresponds to a critical temperature of 1.31 K. This is not suitable to cover the entire W-band. For an 80 nm layer the minimum frequency decreases to 93.2 GHz, which corresponds to a critical temperature of 1.28 K; this value is still suboptimal for W-band operation. Further increase of the Al film thickness results in bad performance of the detector. We have thus considered a Titanium-Aluminum bi-layer (10 nm thick Ti + 25 nm thick Al, already tested in other laboratories), for which we measured a critical temperature of 820 mK and a cut-on frequency of 65 GHz: so this solution allows operation in the entire W-band.
△ Less
Submitted 7 January, 2016;
originally announced January 2016.