-
2023 Astrophotonics Roadmap: pathways to realizing multi-functional integrated astrophotonic instruments
Authors:
Nemanja Jovanovic,
Pradip Gatkine,
Narsireddy Anugu,
Rodrigo Amezcua-Correa,
Ritoban Basu Thakur,
Charles Beichman,
Chad Bender,
Jean-Philippe Berger,
Azzurra Bigioli,
Joss Bland-Hawthorn,
Guillaume Bourdarot,
Charles M. Bradford,
Ronald Broeke,
Julia Bryant,
Kevin Bundy,
Ross Cheriton,
Nick Cvetojevic,
Momen Diab,
Scott A. Diddams,
Aline N. Dinkelaker,
Jeroen Duis,
Stephen Eikenberry,
Simon Ellis,
Akira Endo,
Donald F. Figer
, et al. (55 additional authors not shown)
Abstract:
Photonics offer numerous functionalities that can be used to realize astrophotonic instruments. The most spectacular example to date is the ESO Gravity instrument at the Very Large Telescope in Chile. Integrated astrophotonic devices stand to offer critical advantages for instrument development, including extreme miniaturization, as well as integration, superior thermal and mechanical stabilizatio…
▽ More
Photonics offer numerous functionalities that can be used to realize astrophotonic instruments. The most spectacular example to date is the ESO Gravity instrument at the Very Large Telescope in Chile. Integrated astrophotonic devices stand to offer critical advantages for instrument development, including extreme miniaturization, as well as integration, superior thermal and mechanical stabilization owing to the small footprint, and high replicability offering cost savings. Numerous astrophotonic technologies have been developed to address shortcomings of conventional instruments to date, including for example the development of photonic lanterns, complex aperiodic fiber Bragg gratings, complex beam combiners to enable long baseline interferometry, and laser frequency combs for high precision spectral calibration of spectrometers. Despite these successes, the facility implementation of photonic solutions in astronomical instrumentation is currently limited because of (1) low throughputs from coupling to fibers, coupling fibers to chips, propagation and bend losses, device losses, etc, (2) difficulties with scaling to large channel count devices needed for large bandwidths and high resolutions, and (3) efficient integration of photonics with detectors, to name a few. In this roadmap, we identify 24 areas that need further development. We outline the challenges and advances needed across those areas covering design tools, simulation capabilities, fabrication processes, the need for entirely new components, integration and hybridization and the characterization of devices. To realize these advances the astrophotonics community will have to work cooperatively with industrial partners who have more advanced manufacturing capabilities. With the advances described herein, multi-functional instruments will be realized leading to novel observing capabilities for both ground and space platforms.
△ Less
Submitted 1 November, 2023;
originally announced November 2023.
-
Photonic spectro-interferometry with SCExAO/FIRST at the Subaru Telescope: towards H-alpha imaging of protoplanets
Authors:
Sébastien Vievard,
Manon Lallement,
Elsa Huby,
Sylvestre Lacour,
Olivier Guyon,
Nemanja Jovanovic,
Sergio Leon-saval,
Julien Lozi,
Vincent Deo,
Kyohoon Ahn,
Nick Cvetojevic,
Kevin Barjot,
Guillermo Martin,
Harry-Dean Kenchington-Goldsmith,
Gaspard Duchêne,
Takayuki Kotani,
Franck Marchis,
Daniel Rouan,
Michael Fitzgerald,
Steph Sallum,
Barnaby Norris,
Chris Betters,
Pradip Gatkine,
John Lin,
Yoo Jung Kim
, et al. (5 additional authors not shown)
Abstract:
FIRST is a post Extreme Adaptive-Optics (ExAO) spectro-interferometer operating in the Visible (600-800 nm, R~400). Its exquisite angular resolution (a sensitivity analysis of on-sky data shows that bright companions can be detected down to 0.25lambda/D) combined with its sensitivity to pupil phase discontinuities (from a few nm up to dozens of microns) makes FIRST an ideal self-calibrated solutio…
▽ More
FIRST is a post Extreme Adaptive-Optics (ExAO) spectro-interferometer operating in the Visible (600-800 nm, R~400). Its exquisite angular resolution (a sensitivity analysis of on-sky data shows that bright companions can be detected down to 0.25lambda/D) combined with its sensitivity to pupil phase discontinuities (from a few nm up to dozens of microns) makes FIRST an ideal self-calibrated solution for enabling exoplanet detection and characterization in the future. We present the latest on-sky results along with recent upgrades, including the integration and on-sky test of a new spectrograph (R~3,600) optimized for the detection of H-alpha emission from young exoplanets accreting matter.
△ Less
Submitted 28 August, 2023;
originally announced August 2023.
-
Single-aperture spectro-interferometry in the visible at the Subaru telescope with FIRST: First on-sky demonstration on Keho'oea (α Lyrae) and Hokulei (α Aurigae)
Authors:
Sébastien Vievard,
Elsa Huby,
Sylvestre Lacour,
Olivier Guyon,
Nick Cvetojevic,
Nemanja Jovanovic,
Julien Lozi,
Kevin Barjot,
Vincent Deo,
Gaspard Duchêne,
Takayuki Kotani,
Franck Marchis,
Daniel Rouan,
Guillermo Martin,
Manon Lallement,
Vincent Lapeyrere,
Frantz Martinache,
Kyohoon Ahn,
Nour Skaf,
Motohide Tamura,
Leilehua Yuen,
Leinani Lozi,
Guy Perrin
Abstract:
FIRST is a spectro-interferometer combining, in the visible, the techniques of aperture masking and spatial filtering thanks to single-mode fibers. This instrument aims to deliver high contrast capabilities at spatial resolutions that are inaccessible to classical coronagraphic instruments. The technique implemented is called pupil remapping: the telescope is divided into subpupils by a segmented…
▽ More
FIRST is a spectro-interferometer combining, in the visible, the techniques of aperture masking and spatial filtering thanks to single-mode fibers. This instrument aims to deliver high contrast capabilities at spatial resolutions that are inaccessible to classical coronagraphic instruments. The technique implemented is called pupil remapping: the telescope is divided into subpupils by a segmented deformable mirror conjugated to a micro-lens array injecting light into single-mode fibers. The fiber outputs are rearranged in a nonredundant configuration, allowing simultaneous measurement of all baseline fringe patterns. The fringes are also spectrally dispersed, increasing the coherence length and providing precious spectral information. The optical setup of the instrument has been adapted to fit onto the SCExAO platform at the Subaru Telescope. We present the first on-sky demonstration of the FIRST instrument at the Subaru telescope. We used eight subapertures, each with a diameter of about 1 m. Closure phase measurements were extracted from the interference pattern to provide spatial information on the target. We tested the instrument on two types of targets : a point source (Keho'oea) and a binary system (Hokulei). An average accuracy of 0.6 degree is achieved on the closure phase measurements of Keho'oea, with a statistical error of about 0.15 degree at best. We estimate that the instrument can be sensitive to structures down to a quarter of the telescope spatial resolution. We measured the relative positions of Hokulei Aa and Ab with an accuracy about 1 mas. FIRST opens new observing capabilities in the visible wavelength range at the Subaru Telescope. With SCExAO being a testing platform for high contrast imaging instrumentation for future 30-meter class telescopes, FIRST is an important stepping stone for future interferometric instrumentation on extremely large telescopes.
△ Less
Submitted 19 July, 2023;
originally announced July 2023.
-
Controlling petals using fringes: discontinuous wavefront sensing through sparse aperture interferometry at Subaru/SCExAO
Authors:
Vincent Deo,
Sébastien Vievard,
Nick Cvetojevic,
Kyohoon Ahn,
Elsa Huby,
Olivier Guyon,
Sylvestre Lacour,
Julien Lozi,
Frantz Martinache,
Barnaby Norris,
Nour Skaf,
Peter Tuthill
Abstract:
Low wind and petaling effects, caused by the discontinuous apertures of telescopes, are poorly corrected -- if at all -- by commonly used workhorse wavefront sensors (WFSs). Wavefront petaling breaks the coherence of the point spread function core, splitting it into several side lobes, dramatically shutting off scientific throughput. We demonstrate the re-purposing of non-redundant sparse aperture…
▽ More
Low wind and petaling effects, caused by the discontinuous apertures of telescopes, are poorly corrected -- if at all -- by commonly used workhorse wavefront sensors (WFSs). Wavefront petaling breaks the coherence of the point spread function core, splitting it into several side lobes, dramatically shutting off scientific throughput. We demonstrate the re-purposing of non-redundant sparse aperture masking (SAM) interferometers into low-order WFSs complementing the high-order pyramid WFS, on the SCExAO experimental platform at Subaru Telescope. The SAM far-field interferograms formed from a 7-hole mask are used for direct retrieval of petaling aberrations, which are almost invisible to the main AO loop. We implement a visible light dual-band SAM mode, using two disjoint 25 nm wide channels, that we recombine to overcome the one-lambda ambiguity of fringe-tracking techniques. This enables a control over petaling with sufficient capture range yet without conflicting with coronagraphic modes in the near-infrared. We present on-sky engineering results demonstrating that the design is able to measure petaling well beyond the range of a single-wavelength equivalent design.
△ Less
Submitted 6 September, 2022;
originally announced September 2022.
-
Upgrading the high contrast imaging facility SPHERE: science drivers and instrument choices
Authors:
A. Boccaletti,
G. Chauvin,
F. Wildi,
J. Milli,
E. Stadler,
E. Diolaiti,
R. Gratton,
F. Vidal,
M. Loupias,
M. Langlois,
F. Cantalloube,
M. N'Diaye,
D. Gratadour,
F. Ferreira,
M. Tallon,
J. Mazoyer,
D. Segransan,
D. Mouillet,
J. -L. Beuzit,
M. Bonnefoy,
R. Galicher,
A. Vigan,
I. Snellen,
M. Feldt,
S. Desidera
, et al. (49 additional authors not shown)
Abstract:
SPHERE+ is a proposed upgrade of the SPHERE instrument at the VLT, which is intended to boost the current performances of detection and characterization for exoplanets and disks. SPHERE+ will also serve as a demonstrator for the future planet finder (PCS) of the European ELT. The main science drivers for SPHERE+ are 1/ to access the bulk of the young giant planet population down to the snow line (…
▽ More
SPHERE+ is a proposed upgrade of the SPHERE instrument at the VLT, which is intended to boost the current performances of detection and characterization for exoplanets and disks. SPHERE+ will also serve as a demonstrator for the future planet finder (PCS) of the European ELT. The main science drivers for SPHERE+ are 1/ to access the bulk of the young giant planet population down to the snow line ($3-10$ au), to bridge the gap with complementary techniques (radial velocity, astrometry); 2/ to observe fainter and redder targets in the youngest ($1-10$\,Myr) associations compared to those observed with SPHERE to directly study the formation of giant planets in their birth environment; 3/ to improve the level of characterization of exoplanetary atmospheres by increasing the spectral resolution in order to break degeneracies in giant planet atmosphere models. Achieving these objectives requires to increase the bandwidth of the xAO system (from $\sim$1 to 3\,kHz) as well as the sensitivity in the infrared (2 to 3\,mag). These features will be brought by a second stage AO system optimized in the infrared with a pyramid wavefront sensor. As a new science instrument, a medium resolution integral field spectrograph will provide a spectral resolution from 1000 to 5000 in the J and H bands. This paper gives an overview of the science drivers, requirements and key instrumental trade-off that were done for SPHERE+ to reach the final selected baseline concept.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
The vector-apodizing phase plate coronagraph: design, current performance, and future development
Authors:
D. S. Doelman,
F. Snik,
E. H. Por,
S. P. Bos,
G. P. P. L. Otten,
M. Kenworthy,
S. Y. Haffert,
M. Wilby,
A. J. Bohn,
B. J. Sutlieff,
K. Miller,
M. Ouellet,
J. de Boer,
C. U. Keller,
M. J. Escuti,
S. Shi,
N. Z. Warriner,
K. J. Hornburg,
J. L. Birkby,
J. Males,
K. M. Morzinski,
L. M. Close,
J. Codona,
J. Long,
L. Schatz
, et al. (28 additional authors not shown)
Abstract:
Over the last decade, the vector-apodizing phase plate (vAPP) coronagraph has been developed from concept to on-sky application in many high-contrast imaging systems on 8-m class telescopes. The vAPP is an geometric-phase patterned coronagraph that is inherently broadband, and its manufacturing is enabled only by direct-write technology for liquid-crystal patterns. The vAPP generates two coronagra…
▽ More
Over the last decade, the vector-apodizing phase plate (vAPP) coronagraph has been developed from concept to on-sky application in many high-contrast imaging systems on 8-m class telescopes. The vAPP is an geometric-phase patterned coronagraph that is inherently broadband, and its manufacturing is enabled only by direct-write technology for liquid-crystal patterns. The vAPP generates two coronagraphic PSFs that cancel starlight on opposite sides of the point spread function (PSF) and have opposite circular polarization states. The efficiency, that is the amount of light in these PSFs, depends on the retardance offset from half-wave of the liquid-crystal retarder. Using different liquid-crystal recipes to tune the retardance, different vAPPs operate with high efficiencies ($>96\%$) in the visible and thermal infrared (0.55 $μ$m to 5 $μ$m). Since 2015, seven vAPPs have been installed in a total of six different instruments, including Magellan/MagAO, Magellan/MagAO-X, Subaru/SCExAO, and LBT/LMIRcam. Using two integral field spectrographs installed on the latter two instruments, these vAPPs can provide low-resolution spectra (R$\sim$30) between 1 $μ$m and 5 $μ$m. We review the design process, development, commissioning, on-sky performance, and first scientific results of all commissioned vAPPs. We report on the lessons learned and conclude with perspectives for future developments and applications.
△ Less
Submitted 4 November, 2021; v1 submitted 22 April, 2021;
originally announced April 2021.
-
Laboratory characterization of FIRSTv2 photonic chip for the study of substellar companions
Authors:
K. Barjot,
E. Huby,
S. Vievard,
N. Cvetojevic,
S. Lacour,
G. Martin,
V. Deo,
V. Lapeyrere,
D. Rouan,
O. Guyon,
J. Lozi,
N. Jovanovic,
C. Cassagenettes,
G. Perrin,
F. Marchis,
G. Duchêne,
T. Kotani
Abstract:
FIRST (Fibered Imager foR a Single Telescope instrument) is a post-AO instrument that enables high contrast imaging and spectroscopy at spatial scales below the diffraction limit. FIRST achieves sensitivity and accuracy by a unique combination of sparse aperture masking, spatial filtering by single-mode fibers and cross-dispersion in the visible. The telescope pupil is divided into sub-pupils by a…
▽ More
FIRST (Fibered Imager foR a Single Telescope instrument) is a post-AO instrument that enables high contrast imaging and spectroscopy at spatial scales below the diffraction limit. FIRST achieves sensitivity and accuracy by a unique combination of sparse aperture masking, spatial filtering by single-mode fibers and cross-dispersion in the visible. The telescope pupil is divided into sub-pupils by an array of microlenses, coupling the light into single-mode fibers. The output of the fibers are rearranged in a non redundant configuration, allowing the measurement of the complex visibility for every baseline over the 600-900 nm spectral range. A first version of this instrument is currently integrated to the Subaru Extreme AO bench (SCExAO). This paper focuses on the on-going instrument upgrades and testings, which aim at increasing the instrument's stability and sensitivity, thus improving the dynamic range. FIRSTv2's interferometric scheme is based on a photonic chip beam combiner. We report on the laboratory characterization of two different types of 5-input beam combiner with enhanced throughput. The interferometric recombination of each pair of sub-pupils is encoded on a single output. Thus, to sample the fringes we implemented a temporal phase modulation by pistoning the segmented mirrors of a Micro-ElectroMechanical System (MEMS). By coupling high angular resolution and spectral resolution in the visible, FIRST offers unique capabilities in the context of the detection and spectral characterization of close companions, especially on 30m-class telescopes.
△ Less
Submitted 12 February, 2021;
originally announced February 2021.
-
Imaging low-mass planets within the habitable zone of α Centauri
Authors:
K. Wagner,
A. Boehle,
P. Pathak,
M. Kasper,
R. Arsenault,
G. Jakob,
U. Kaufl,
S. Leveratto,
A. -L. Maire,
E. Pantin,
R. Siebenmorgen,
G. Zins,
O. Absil,
N. Ageorges,
D. Apai,
A. Carlotti,
É. Choquet,
C. Delacroix,
K. Dohlen,
P. Duhoux,
P. Forsberg,
E. Fuenteseca,
S. Gutruf,
O. Guyon,
E. Huby
, et al. (17 additional authors not shown)
Abstract:
Giant exoplanets on wide orbits have been directly imaged around young stars. If the thermal background in the mid-infrared can be mitigated, then exoplanets with lower masses can also be imaged. Here we present a ground-based mid-infrared observing approach that enables imaging low-mass temperate exoplanets around nearby stars, and in particular within the closest stellar system, Alpha Centauri.…
▽ More
Giant exoplanets on wide orbits have been directly imaged around young stars. If the thermal background in the mid-infrared can be mitigated, then exoplanets with lower masses can also be imaged. Here we present a ground-based mid-infrared observing approach that enables imaging low-mass temperate exoplanets around nearby stars, and in particular within the closest stellar system, Alpha Centauri. Based on 75-80% of the best quality images from 100 hours of cumulative observations, we demonstrate sensitivity to warm sub-Neptune-sized planets throughout much of the habitable zone of Alpha Centauri A. This is an order of magnitude more sensitive than state-of-the-art exoplanet imaging mass detection limits. We also discuss a possible exoplanet or exozodiacal disk detection around Alpha Centauri A. However, an instrumental artifact of unknown origin cannot be ruled out. These results demonstrate the feasibility of imaging rocky habitable-zone exoplanets with current and upcoming telescopes.
△ Less
Submitted 13 April, 2021; v1 submitted 9 February, 2021;
originally announced February 2021.
-
FIRST, a Pupil-Remapping Fiber Interferometer at the Subaru Telescope: on-sky results
Authors:
Sébastien Vievard,
Elsa Huby,
Sylvestre Lacour,
Kevin Barjot,
Guillermo Martin,
Nick Cvetojevic,
Vincent Deo,
Olivier Guyon,
Julien Lozi,
Takayuki Kotani,
Nemanja Jovanovic,
Franck Marchis,
Guillaume Duchène,
Vincent Lapeyrere,
Daniel Rouan,
Guy Perrin
Abstract:
FIRST, the Fibered Imager foR a Single Telescope, is a spectro-imager using single-mode fibers for pupil remapping, allowing measurements beyond the telescope diffraction limit. Integrated on the Subaru Coronagraphic Extreme Adaptive Optics instrument at the Subaru Telescope, it benefits from a very stable visible light wavefront allowing to acquire long exposure and operate on significantly faint…
▽ More
FIRST, the Fibered Imager foR a Single Telescope, is a spectro-imager using single-mode fibers for pupil remapping, allowing measurements beyond the telescope diffraction limit. Integrated on the Subaru Coronagraphic Extreme Adaptive Optics instrument at the Subaru Telescope, it benefits from a very stable visible light wavefront allowing to acquire long exposure and operate on significantly fainter sources than previously possible. On-sky results demonstrated the ability of the instrument to detect stellar companions separated 43mas in the case of the Capella binary system. A similar approach on an extremely large telescope would offer unique scientific opportunities for companion detection and characterization at very high angular resolution.
△ Less
Submitted 22 December, 2020;
originally announced December 2020.
-
Socio-demographic study of the exoplanet direct imaging community
Authors:
Lucie Leboulleux,
Élodie Choquet,
Elsa Huby,
Garima Singh,
Faustine Cantalloube
Abstract:
Astronomy and science are fields in which specific groups remain under-represented despite multiple studies that investigate this issue and propose solutions. In this article, we analyze the demographics and social behavior of the exoplanet direct imaging community. Our focus is on identifying possible under-representation among this group, and quantifying inappropriate social behaviors. During th…
▽ More
Astronomy and science are fields in which specific groups remain under-represented despite multiple studies that investigate this issue and propose solutions. In this article, we analyze the demographics and social behavior of the exoplanet direct imaging community. Our focus is on identifying possible under-representation among this group, and quantifying inappropriate social behaviors. During the Spirit of Lyot conference 2019 (Tokyo, Japan), we conducted a survey that gathered a participation rate of 53\%. We analyzed the data collected under the prisms of gender balance and seniority representation. The proportions of women and of non-binary persons reveal a more diverse community in comparison to the other scientific groups (e.g. the IAU members), but still far from a balanced representation of all genders. Early-career scientists appear to have a lower visibility in the field than permanent researchers, with PhD students being under-represented at international conferences, and postdocs being excluded from conference Science Organizing Committees. Regarding social relations, the results are alarming, in particular when it comes to self-censoring of women or to unprofessional behavior, which was experienced by 54\% of this community (gender-biased behavior: 29\%; oral interruption: 33\%; inappropriate behavior: 33\%), and in particular by women. We recommend the community to become pro-active to build a safe environment and to continue its inclusion efforts. One aspect could be to systematically include socio-demographic surveys in conference registration forms to monitor the evolution of the community, in particular at larger scales. To do so, the survey questions available on GitHub.
△ Less
Submitted 21 December, 2020;
originally announced December 2020.
-
Design, pointing control, and on-sky performance of the mid-infrared vortex coronagraph for the VLT/NEAR experiment
Authors:
A. -L. Maire,
E. Huby,
O. Absil,
G. Zins,
M. Kasper,
C. Delacroix,
S. Leveratto,
M. Karlsson,
G. Ruane,
H. -U. Käufl,
G. Orban de Xivry,
P. Pathak,
L. Pettazzi,
P. Duhoux,
J. Kolb,
E. Pantin,
A. J. Eldorado Riggs,
R. Siebenmorgen,
D. Mawet
Abstract:
Vortex coronagraphs have been shown to be a promising avenue for high-contrast imaging in the close-in environment of stars at thermal infrared (IR) wavelengths. They are included in the baseline design of METIS. To ensure good performance of these coronagraphs, a precise control of the centering of the star image in real time is needed. We previously developed and validated the quadrant analysis…
▽ More
Vortex coronagraphs have been shown to be a promising avenue for high-contrast imaging in the close-in environment of stars at thermal infrared (IR) wavelengths. They are included in the baseline design of METIS. To ensure good performance of these coronagraphs, a precise control of the centering of the star image in real time is needed. We previously developed and validated the quadrant analysis of coronagraphic images for tip-tilt sensing estimator (QACITS) pointing estimator to address this issue. While this approach is not wavelength-dependent in theory, it was never implemented for mid-IR observations, which leads to specific challenges and limitations. Here, we present the design of the mid-IR vortex coronagraph for the new Earths in the $α$ Cen Region (NEAR) experiment with the VLT/VISIR instrument and assess the performance of the QACITS estimator for the centering control of the star image onto the vortex coronagraph. We use simulated data and on-sky data obtained with VLT/VISIR, which was recently upgraded for observations assisted by adaptive optics in the context of the NEAR experiment. We demonstrate that the QACITS-based correction loop is able to control the centering of the star image onto the NEAR vortex coronagraph with a stability down to $0.015 λ/D$ rms over 4h in good conditions. These results show that QACITS is a robust approach for precisely controlling in real time the centering of vortex coronagraphs for mid-IR observations.
△ Less
Submitted 15 December, 2020;
originally announced December 2020.
-
High contrast imaging for the enhanced resolution imager and spectrometer (ERIS)
Authors:
Matthew A. Kenworthy,
Frans Snik,
Christoph U. Keller,
David Doelman,
Emiel H. Por,
Olivier Absil,
Brunella Carlomagno,
Mikael Karlsson,
Elsa Huby,
Adrian M. Glauser,
Sascha P. Quanz,
William D. Taylor
Abstract:
ERIS is a diffraction limited thermal infrared imager and spectrograph for the Very Large Telescope UT4. One of the science cases for ERIS is the detection and characterization of circumstellar structures and exoplanets around bright stars that are typically much fainter than the stellar diffraction halo. Enhanced sensitivity is provided through the combination of (i) suppression of the diffractio…
▽ More
ERIS is a diffraction limited thermal infrared imager and spectrograph for the Very Large Telescope UT4. One of the science cases for ERIS is the detection and characterization of circumstellar structures and exoplanets around bright stars that are typically much fainter than the stellar diffraction halo. Enhanced sensitivity is provided through the combination of (i) suppression of the diffraction halo of the target star using coronagraphs, and (ii) removal of any residual diffraction structure through focal plane wavefront sensing and subsequent active correction. In this paper we present the two coronagraphs used for diffraction suppression and enabling high contrast imaging in ERIS.
△ Less
Submitted 3 December, 2020;
originally announced December 2020.
-
Capabilities of a fibered imager on an extremely large telescope
Authors:
Sebastien Vievard,
Nick Cvetojevic,
Elsa Huby,
Sylvestre Lacour,
Guillermo Martin,
Olivier Guyon,
Julien Lozi,
Takayuki Kotani,
Nemanja Jovanovic,
Guy Perrin,
Franck Marchis,
Olivier Lai,
Vincent Lapeyrere,
Daniel Rouan
Abstract:
FIRST, the Fibered Imager foR a Single Telescope instrument, is an ultra-high angular resolution spectro-imager, able to deliver calibrated images and measurements beyond the telescope diffraction limit, a regime that is out of reach for conventional AO imaging. FIRST achieves sensitivity and accuracy by coupling the full telescope to an array of single mode fibers. Interferometric fringes are spe…
▽ More
FIRST, the Fibered Imager foR a Single Telescope instrument, is an ultra-high angular resolution spectro-imager, able to deliver calibrated images and measurements beyond the telescope diffraction limit, a regime that is out of reach for conventional AO imaging. FIRST achieves sensitivity and accuracy by coupling the full telescope to an array of single mode fibers. Interferometric fringes are spectrally dispersed and imaged on an EMCCD. An 18-Fiber FIRST setup is currently installed on the Subaru Coronographic Extreme Adaptive Optics instrument at Subaru telescope. It is being exploited for binary star system study. In the late 2020 it will be upgraded with delay lines and an active LiNb03 photonic beam-combining chip allowing phase modulation to nanometer accuracy at MHz. On-sky results at Subaru Telescope have demonstrated that, thanks to the ExAO system stabilizing the visible light wavefront, FIRST can acquire long exposure and operate on significantly fainter sources than previously possible. A similar approach on a larger telescope would therefore offer unique scientific opportunities for galactic (stellar physics, close companions) and extragalactic observations at ultra-high angular resolution. We also discuss potential design variations for nulling and high contrast imaging.
△ Less
Submitted 20 October, 2020;
originally announced October 2020.
-
Increasing the raw contrast of VLT/SPHERE with the dark hole technique. I. Simulations and validation on the internal source
Authors:
Axel Potier,
Raphaël Galicher,
Pierre Baudoz,
Elsa Huby,
Julien Milli,
Zahed Wahhaj,
Anthony Boccaletti,
Arthur Vigan,
Mamadou N'Diaye,
Jean-François Sauvage
Abstract:
Context. Since 1995 and the first discovery of an exoplanet orbiting a main-sequence star, 4000 exoplanets have been discovered using several techniques. However, only a few of these exoplanets were detected through direct imaging. Indeed, the imaging of circumstellar environments requires high-contrast imaging facilities and accurate control of wavefront aberrations. Ground-based planet imagers s…
▽ More
Context. Since 1995 and the first discovery of an exoplanet orbiting a main-sequence star, 4000 exoplanets have been discovered using several techniques. However, only a few of these exoplanets were detected through direct imaging. Indeed, the imaging of circumstellar environments requires high-contrast imaging facilities and accurate control of wavefront aberrations. Ground-based planet imagers such as VLT/SPHERE or Gemini/GPI have already demonstrated great performance. However, their limit of detection is hampered by suboptimal correction of aberrations unseen by adaptive optics (AO). Aims. Instead of focusing on the phase minimization of the pupil plane as in standard AO, we aim to directly minimize the stellar residual light in the SPHERE science camera behind the coronagraph to improve the contrast as close as possible to the inner working angle. Methods. We propose a dark hole (DH) strategy optimized for SPHERE. We used a numerical simulation to predict the global improvement of such a strategy on the overall performance of the instrument for different AO capabilities and particularly in the context of a SPHERE upgrade. Then, we tested our algorithm on the internal source with the AO in closed loop. Results. We demonstrate that our DH strategy can correct for aberrations of phase and amplitude. Moreover, this approach has the ability to strongly reduce the diffraction pattern induced by the telescope pupil and the coronagraph, unlike methods operating at the pupil plane. Our strategy enables us to reach a contrast of 5e-7 at 150 mas from the optical axis in a few minutes using the SPHERE internal source. This experiment establishes the grounds for implementing the algorithm on sky in the near future.
△ Less
Submitted 5 May, 2020;
originally announced May 2020.
-
Keck/NIRC2 $L$'-Band Imaging of Jovian-Mass Accreting Protoplanets around PDS 70
Authors:
Jason J. Wang,
Sivan Ginzburg,
Bin Ren,
Nicole Wallack,
Peter Gao,
Dimitri Mawet,
Charlotte Z. Bond,
Sylvain Cetre,
Peter Wizinowich,
Robert J. De Rosa,
Garreth Ruane,
Michael C. Liu,
Olivier Absil,
Carlos Alvarez,
Christoph Baranec,
Élodie Choquet,
Mark Chun,
Denis Defrère,
Jacques-Robert Delorme,
Gaspard Duchêne,
Pontus Forsberg,
Andrea Ghez,
Olivier Guyon,
Donald N. B. Hall,
Elsa Huby
, et al. (20 additional authors not shown)
Abstract:
We present $L$'-band imaging of the PDS 70 planetary system with Keck/NIRC2 using the new infrared pyramid wavefront sensor. We detected both PDS 70 b and c in our images, as well as the front rim of the circumstellar disk. After subtracting off a model of the disk, we measured the astrometry and photometry of both planets. Placing priors based on the dynamics of the system, we estimated PDS 70 b…
▽ More
We present $L$'-band imaging of the PDS 70 planetary system with Keck/NIRC2 using the new infrared pyramid wavefront sensor. We detected both PDS 70 b and c in our images, as well as the front rim of the circumstellar disk. After subtracting off a model of the disk, we measured the astrometry and photometry of both planets. Placing priors based on the dynamics of the system, we estimated PDS 70 b to have a semi-major axis of $20^{+3}_{-4}$~au and PDS 70 c to have a semi-major axis of $34^{+12}_{-6}$~au (95\% credible interval). We fit the spectral energy distribution (SED) of both planets. For PDS 70 b, we were able to place better constraints on the red half of its SED than previous studies and inferred the radius of the photosphere to be 2-3~$R_{Jup}$. The SED of PDS 70 c is less well constrained, with a range of total luminosities spanning an order of magnitude. With our inferred radii and luminosities, we used evolutionary models of accreting protoplanets to derive a mass of PDS 70 b between 2 and 4 $M_{\textrm{Jup}}$ and a mean mass accretion rate between $3 \times 10^{-7}$ and $8 \times 10^{-7}~M_{\textrm{Jup}}/\textrm{yr}$. For PDS 70 c, we computed a mass between 1 and 3 $M_{\textrm{Jup}}$ and mean mass accretion rate between $1 \times 10^{-7}$ and $5 \times~10^{-7} M_{\textrm{Jup}}/\textrm{yr}$. The mass accretion rates imply dust accretion timescales short enough to hide strong molecular absorption features in both planets' SEDs.
△ Less
Submitted 20 May, 2020; v1 submitted 20 April, 2020;
originally announced April 2020.
-
SPHERE+: Imaging young Jupiters down to the snowline
Authors:
A. Boccaletti,
G. Chauvin,
D. Mouillet,
O. Absil,
F. Allard,
S. Antoniucci,
J. -C. Augereau,
P. Barge,
A. Baruffolo,
J. -L. Baudino,
P. Baudoz,
M. Beaulieu,
M. Benisty,
J. -L. Beuzit,
A. Bianco,
B. Biller,
B. Bonavita,
M. Bonnefoy,
S. Bos,
J. -C. Bouret,
W. Brandner,
N. Buchschache,
B. Carry,
F. Cantalloube,
E. Cascone
, et al. (108 additional authors not shown)
Abstract:
SPHERE (Beuzit et al,. 2019) has now been in operation at the VLT for more than 5 years, demonstrating a high level of performance. SPHERE has produced outstanding results using a variety of operating modes, primarily in the field of direct imaging of exoplanetary systems, focusing on exoplanets as point sources and circumstellar disks as extended objects. The achievements obtained thus far with S…
▽ More
SPHERE (Beuzit et al,. 2019) has now been in operation at the VLT for more than 5 years, demonstrating a high level of performance. SPHERE has produced outstanding results using a variety of operating modes, primarily in the field of direct imaging of exoplanetary systems, focusing on exoplanets as point sources and circumstellar disks as extended objects. The achievements obtained thus far with SPHERE (~200 refereed publications) in different areas (exoplanets, disks, solar system, stellar physics...) have motivated a large consortium to propose an even more ambitious set of science cases, and its corresponding technical implementation in the form of an upgrade. The SPHERE+ project capitalizes on the expertise and lessons learned from SPHERE to push high contrast imaging performance to its limits on the VLT 8m-telescope. The scientific program of SPHERE+ described in this document will open a new and compelling scientific window for the upcoming decade in strong synergy with ground-based facilities (VLT/I, ELT, ALMA, and SKA) and space missions (Gaia, JWST, PLATO and WFIRST). While SPHERE has sampled the outer parts of planetary systems beyond a few tens of AU, SPHERE+ will dig into the inner regions around stars to reveal and characterize by mean of spectroscopy the giant planet population down to the snow line. Building on SPHERE's scientific heritage and resounding success, SPHERE+ will be a dedicated survey instrument which will strengthen the leadership of ESO and the European community in the very competitive field of direct imaging of exoplanetary systems. With enhanced capabilities, it will enable an even broader diversity of science cases including the study of the solar system, the birth and death of stars and the exploration of the inner regions of active galactic nuclei.
△ Less
Submitted 13 March, 2020; v1 submitted 12 March, 2020;
originally announced March 2020.
-
A Family of Phase Masks For Broadband Coronagraphy Example of the Wrapped Vortex Phase Mask Theory and Laboratory demonstration
Authors:
Raphaël Galicher,
Pierre Baudoz,
Elsa Huby,
Olivier Dupuis
Abstract:
Future instruments need efficient coronagraphs over large spectral ranges to enable broadband imaging or spectral characterization of exoplanets 1e8 fainter than their star. Several solutions were proposed. Pupil apodizers can attenuate the star intensity by a 1e10 factor but they transmit a few percents of the planet light only. Cascades of phase/amplitude masks can both attenuate the starlight a…
▽ More
Future instruments need efficient coronagraphs over large spectral ranges to enable broadband imaging or spectral characterization of exoplanets 1e8 fainter than their star. Several solutions were proposed. Pupil apodizers can attenuate the star intensity by a 1e10 factor but they transmit a few percents of the planet light only. Cascades of phase/amplitude masks can both attenuate the starlight and transmit most of the planet light but the number of optics to align is not a practical solution for an instrument. Finally, vector phase masks can be used to detect faint sources close to bright stars but they require the use of high quality circular polarizers and as for the previous solution, this leads to a complex instrument with numerous optics to align and stabilize. We propose simple coronagraphs that need one scalar phase mask and one binary Lyot stop only providing high transmission for the planet light (>50%) and high attenuation of the starlight over a large spectral bandpass (~30%) and a 360 degree field-of-view. From mathematical considerations, we find a family of 2D-phase masks optimized for an unobscured pupil. One mask is an azimuthal wrapped vortex phase ramp. We probe its coronagraphic performance using numerical simulations and laboratory tests. From numerical simulations, we predict the wrapped vortex can attenuate the peak of the star image by a factor of 1e4 over a 29% bandpass and 1e5 over a 18% bandpass with transmission of more than 50% of the planet flux at ~4 lambda/D. We confirm these predictions in laboratory in visible light between 550nm and 870nm. We also obtain laboratory dark hole images in which exoplanets with fluxes that are 3e-8 times the host star flux could be detected at 3sigma. Taking advantage of a new technology for etching continuous 2D-functions, new type of masks can be easily manufactured opening new possibilities for broadband coronagraphy.
△ Less
Submitted 16 January, 2020;
originally announced January 2020.
-
Exoplanet direct imaging in ground-based conditions on THD2 bench
Authors:
A. Potier,
P. Baudoz,
R. Galicher,
E. Huby,
G. Singh
Abstract:
The next generation of ground-based instruments aims to break through the knowledge we have on exoplanets by imaging circumstellar environments always closer to the stars. However, direct imaging requires an AO system and high-contrast techniques like a coronagraph to reject the diffracted light of an observed star and an additional wavefront sensor to control quasi-static aberrations, including t…
▽ More
The next generation of ground-based instruments aims to break through the knowledge we have on exoplanets by imaging circumstellar environments always closer to the stars. However, direct imaging requires an AO system and high-contrast techniques like a coronagraph to reject the diffracted light of an observed star and an additional wavefront sensor to control quasi-static aberrations, including the non common path aberrations. To observe faint objects, a focal plane wavefront sensor with a sub-nanometric wavefront control capability is required. In the past few years, we developed the THD2 bench which is a testbed for high-contrast imaging techniques, working in visible and near infrared wavelengths and currently reaching contrast levels lower than 1e-8 under space-like simulated conditions. We recently added a turbulence wheel on the optical path which simulates the residuals given by a typical extreme adaptive optics system and we tested several ways to remove quasi-statics speckles. One way to estimate the aberrations is a method called pair-wise probing where we record few images with known-shapes we apply on the adaptive optics deformable mirror. Once estimated, we seek to minimize the focal-plane electric field by an algorithm called Electric Field Conjugation. In this paper, we present the first results obtained on the THD2 bench using these two techniques together in turbulent conditions. We then compare the achieved performance with the one expected when all the quasi-static speckles are corrected.
△ Less
Submitted 20 October, 2019;
originally announced October 2019.
-
Near-Infrared Imaging of a Spiral in the CQ Tau Disk
Authors:
Taichi Uyama,
Takayuki Muto,
Dimitri Mawet,
Valentin Christiaens,
Jun Hashimoto,
Tomoyuki Kudo,
Masayuki Kuzuhara,
Garreth Ruane,
Charles Beichman,
Olivier Absil,
Eiji Akiyama,
Jaehan Bae,
Michael Bottom,
Elodie Choquet,
Thayne Currie,
Ruobing Dong,
Katherine B. Follette,
Misato Fukagawa,
Greta Guidi,
Elsa Huby,
Jungmi Kwon,
Satoshi Mayama,
Tiffany Meshkat,
Maddalena Reggiani,
Luca Ricci
, et al. (6 additional authors not shown)
Abstract:
We present $L^\prime$-band Keck/NIRC2 imaging and $H$-band Subaru/AO188+HiCIAO polarimetric observations of CQ Tau disk with a new spiral arm. Apart from the spiral feature our observations could not detect any companion candidates. We traced the spiral feature from the $r^2$-scaled HiCIAO polarimetric intensity image and the fitted result is used for forward modeling to reproduce the ADI-reduced…
▽ More
We present $L^\prime$-band Keck/NIRC2 imaging and $H$-band Subaru/AO188+HiCIAO polarimetric observations of CQ Tau disk with a new spiral arm. Apart from the spiral feature our observations could not detect any companion candidates. We traced the spiral feature from the $r^2$-scaled HiCIAO polarimetric intensity image and the fitted result is used for forward modeling to reproduce the ADI-reduced NIRC2 image. We estimated the original surface brightness after throughput correction in $L^\prime$-band to be $\sim126$ mJy/arcsec$^2$ at most. We suggest that the grain temperature of the spiral may be heated up to $\sim$200 K in order to explain both of the $H$- and $L^{\prime}$-bands results. The $H$-band emission at the location of the spiral originates from the scattering from the disk surface while both scattering and thermal emission may contribute to the $L^{\prime}$-band emission. If the central star is only the light source of scattered light, the spiral emission at $L^\prime$-band should be thermal emission. If an inner disk also acts as the light source, the scattered light and the thermal emission may equally contribute to the $L^\prime$-band spiral structure.
△ Less
Submitted 24 January, 2020; v1 submitted 16 October, 2019;
originally announced October 2019.
-
Active minimization of non-common path aberrations in long-exposure imaging of exoplanetary systems
Authors:
Garima Singh,
Raphaël Galicher,
Pierre Baudoz,
Olivier Dupuis,
Manuel Ortiz,
Axel Potier,
Simone Thijs,
Elsa Huby
Abstract:
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures…
▽ More
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures, quickly evolving NCPAs average out and leave behind an AO halo that adds photon noise to the planet detection. Static NCPA can be calibrated a posteriori using differential imaging techniques. However, NCPAs that evolve during the observing sequence do not average out and cannot be calibrated a posteriori. These quasi-static NCPAs are one of the main limitations of the current direct imaging instruments such as SPHERE, GPI, and SCExAO.
Aims. Our aim is to actively minimize the quasi-static speckles induced in long-exposure images. To do so, we need to measure the quasi-static speckle field above the AO halo.
Methods. The self-coherent camera (SCC) is a proven technique which measures the speckle complex field in the coronagraphic science images. It is routinely used on the THD2 bench to reach contrast levels of <10^{-8} in the range 5-12 λ/D in space-related conditions. To test the SCC in ground conditions on THD2, we optically simulated the residual aberrations measured behind the SPHERE/VLT AO system under good observing conditions.
Results. We demonstrate in the laboratory that the SCC can minimize the quasi-static speckle intensity in the science images down to a limitation set by the AO halo residuals. The SCC reaches 1σ raw contrast levels below 10^{-6} in the region 5-12 λ/D at 783.25 nm in our experiments.
△ Less
Submitted 1 October, 2019;
originally announced October 2019.
-
ESA Voyage 2050 White Paper: Detecting life outside our solar system with a large high-contrast-imaging mission
Authors:
Ignas Snellen,
Simon Albrecht,
Guillem Anglada-Escude,
Isabelle Baraffe,
Pierre Baudoz,
Willy Benz,
Jean-Luc Beuzit,
Beth Biller,
Jayne Birkby,
Anthony Boccaletti,
Roy van Boekel,
Jos de Boer,
Matteo Brogi,
Lars Buchhave,
Ludmila Carone,
Mark Claire,
Riccardo Claudi,
Brice-Olivier Demory,
Jean-Michel Desert,
Silvano Desidera,
Scott Gaudi,
Raffaele Gratton,
Michael Gillon,
John Lee Grenfell,
Olivier Guyon
, et al. (42 additional authors not shown)
Abstract:
In this white paper, we recommend the European Space Agency plays a proactive role in developing a global collaborative effort to construct a large high-contrast imaging space telescope, e.g. as currently under study by NASA. Such a mission will be needed to characterize a sizable sample of temperate Earth-like planets in the habitable zones of nearby Sun-like stars and to search for extraterrestr…
▽ More
In this white paper, we recommend the European Space Agency plays a proactive role in developing a global collaborative effort to construct a large high-contrast imaging space telescope, e.g. as currently under study by NASA. Such a mission will be needed to characterize a sizable sample of temperate Earth-like planets in the habitable zones of nearby Sun-like stars and to search for extraterrestrial biological activity. We provide an overview of relevant European expertise, and advocate ESA to start a technology development program towards detecting life outside the Solar system.
△ Less
Submitted 5 August, 2019;
originally announced August 2019.
-
Reference star differential imaging of close-in companions and circumstellar disks with the NIRC2 vortex coronagraph at W.M. Keck Observatory
Authors:
Garreth Ruane,
Henry Ngo,
Dimitri Mawet,
Olivier Absil,
Elodie Choquet,
Therese Cook,
Carlos Gomez Gonzalez,
Elsa Huby,
Keith Matthews,
Tiffany Meshkat,
Maddalena Reggiani,
Eugene Serabyn,
Nicole Wallack,
W. Jerry Xuan
Abstract:
Reference star differential imaging (RDI) is a powerful strategy for high contrast imaging. Using example observations taken with the vortex coronagraph mode of Keck/NIRC2 in $L^\prime$ band, we demonstrate that RDI provides improved sensitivity to point sources at small angular separations compared to angular differential imaging (ADI). Applying RDI to images of the low-mass stellar companions HI…
▽ More
Reference star differential imaging (RDI) is a powerful strategy for high contrast imaging. Using example observations taken with the vortex coronagraph mode of Keck/NIRC2 in $L^\prime$ band, we demonstrate that RDI provides improved sensitivity to point sources at small angular separations compared to angular differential imaging (ADI). Applying RDI to images of the low-mass stellar companions HIP 79124 C (192 mas separation, $ΔL^\prime$=4.01) and HIP 78233 B (141 mas separation, $ΔL^\prime$=4.78), the latter a first imaging detection, increases the significance of their detections by up to a factor of 5 with respect to ADI. We compare methods for reference frames selection and find that pre-selection of frames improves detection significance of point sources by up to a factor of 3. In addition, we use observations of the circumstellar disks around MWC 758 and 2MASS J16042165-2130284 to show that RDI allows for accurate mapping of scattered light distributions without self-subtraction artifacts.
△ Less
Submitted 14 January, 2019; v1 submitted 13 January, 2019;
originally announced January 2019.
-
Deep exploration of $ε$ Eridani with Keck Ms-band vortex coronagraphy and radial velocities: mass and orbital parameters of the giant exoplanet
Authors:
Dimitri Mawet,
Lea Hirsch,
Eve J. Lee,
Jean-Baptiste Ruffio,
Michael Bottom,
Benjamin J. Fulton,
Olivier Absil,
Charles Beichman,
Brendan Bowler,
Marta Bryan,
Elodie Choquet,
David Ciardi,
Valentin Christiaens,
Denis Defrère,
Carlos Alberto Gomez Gonzalez,
Andrew W. Howard,
Elsa Huby,
Howard Isaacson,
Rebecca Jensen-Clem,
Molly Kosiarek,
Geoff Marcy,
Tiffany Meshkat,
Erik Petigura,
Maddalena Reggiani,
Garreth Ruane
, et al. (5 additional authors not shown)
Abstract:
We present the most sensitive direct imaging and radial velocity (RV) exploration of $ε$ Eridani to date. $ε$ Eridani is an adolescent planetary system, reminiscent of the early Solar system. It is surrounded by a prominent and complex debris disk which is likely stirred by one or several gas giant exoplanets. The discovery of the RV signature of a giant exoplanet was announced 15 years ago, but h…
▽ More
We present the most sensitive direct imaging and radial velocity (RV) exploration of $ε$ Eridani to date. $ε$ Eridani is an adolescent planetary system, reminiscent of the early Solar system. It is surrounded by a prominent and complex debris disk which is likely stirred by one or several gas giant exoplanets. The discovery of the RV signature of a giant exoplanet was announced 15 years ago, but has met with scrutiny due to possible confusion with stellar noise. We confirm the planet with a new compilation and analysis of precise RV data spanning 30 years, and combine it with upper limits from our direct imaging search, the most sensitive ever performed. The deep images were taken in the Ms band (4.7$μ$m) with the vortex coronagraph recently installed in W.M. Keck Observatory's infrared camera NIRC2, which opens a sensitive window for planet searches around nearby adolescent systems. The RV data and direct imaging upper limit maps were combined in an innovative joint Bayesian analysis, providing new constraints on the mass and orbital parameters of the elusive planet. $ε$ Eridani b has a mass of $0.78^{+0.38}_{-0.12}$ $M_{Jup}$ and is orbiting $ε$ Eridani at about $3.48\pm 0.02$ AU with a period of $7.37 \pm 0.07$ years. The eccentricity of $ε$ Eridani b's orbit is $0.07^{+0.06}_{-0.05}$, an order of magnitude smaller than early estimates and consistent with a circular orbit. We discuss our findings from the standpoint of planet-disk interactions and prospects for future detection and characterization with the James Webb Space Telescope.
△ Less
Submitted 29 October, 2018; v1 submitted 8 October, 2018;
originally announced October 2018.
-
SCExAO, an instrument with a dual purpose: perform cutting-edge science and develop new technologies
Authors:
Julien Lozi,
Olivier Guyon,
Nemanja Jovanovic,
Sean Goebel,
Prashant Pathak,
Nour Skaf,
Ananya Sahoo,
Barnaby Norris,
Frantz Martinache,
Mamadou N'Diaye,
Ben Mazin,
Alex B. Walter,
Peter Tuthill,
Tomoyuki Kudo,
Hajime Kawahara,
Takayuki Kotani,
Michael Ireland,
Nick Cvetojevic,
Elsa Huby,
Sylvestre Lacour,
Sebastien Vievard,
Tyler D. Groff,
Jeffrey K. Chilcote,
Jeremy Kasdin,
Justin Knight
, et al. (9 additional authors not shown)
Abstract:
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is an extremely modular high-contrast instrument installed on the Subaru telescope in Hawaii. SCExAO has a dual purpose. Its position in the northern hemisphere on a 8-meter telescope makes it a prime instrument for the detection and characterization of exoplanets and stellar environments over a large portion of the sky. In addit…
▽ More
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is an extremely modular high-contrast instrument installed on the Subaru telescope in Hawaii. SCExAO has a dual purpose. Its position in the northern hemisphere on a 8-meter telescope makes it a prime instrument for the detection and characterization of exoplanets and stellar environments over a large portion of the sky. In addition, SCExAO's unique design makes it the ideal instrument to test innovative technologies and algorithms quickly in a laboratory setup and subsequently deploy them on-sky. SCExAO benefits from a first stage of wavefront correction with the facility adaptive optics AO188, and splits the 600-2400 nm spectrum towards a variety of modules, in visible and near infrared, optimized for a large range of science cases. The integral field spectrograph CHARIS, with its J, H or K-band high-resolution mode or its broadband low-resolution mode, makes SCExAO a prime instrument for exoplanet detection and characterization. Here we report on the recent developments and scientific results of the SCExAO instrument. Recent upgrades were performed on a number of modules, like the visible polarimetric module VAMPIRES, the high-performance infrared coronagraphs, various wavefront control algorithms, as well as the real-time controller of AO188. The newest addition is the 20k-pixel Microwave Kinetic Inductance Detector (MKIDS) Exoplanet Camera (MEC) that will allow for previously unexplored science and technology developments. MEC, coupled with novel photon-counting speckle control, brings SCExAO closer to the final design of future high-contrast instruments optimized for Giant Segmented Mirror Telescopes (GSMTs).
△ Less
Submitted 21 September, 2018;
originally announced September 2018.
-
Characterizing the performance of the NIRC2 vortex coronagraph at W.M. Keck Observatory
Authors:
W. Jerry Xuan,
Dimitri Mawet,
Henry Ngo,
Garreth Ruane,
Vanessa P. Bailey,
Élodie Choquet,
Olivier Absil,
Carlos Alvarez,
Marta Bryan,
Therese Cook,
Bruno Femenía Castellá,
Carlos Alberto Gomez Gonzalez,
Elsa Huby,
Heather A. Knutson,
Keith Matthews,
Sam Ragland,
Eugene Serabyn,
Zoë Zawol
Abstract:
The NIRC2 vortex coronagraph is an instrument on Keck II designed to directly image exoplanets and circumstellar disks at mid-infrared bands $L^\prime$ (3.4-4.1 $μ$m) and $M_s$ (4.55-4.8 $μ$m). We analyze imaging data and corresponding adaptive optics telemetry, observing conditions, and other metadata over a three year time period to characterize the performance of the instrument and predict the…
▽ More
The NIRC2 vortex coronagraph is an instrument on Keck II designed to directly image exoplanets and circumstellar disks at mid-infrared bands $L^\prime$ (3.4-4.1 $μ$m) and $M_s$ (4.55-4.8 $μ$m). We analyze imaging data and corresponding adaptive optics telemetry, observing conditions, and other metadata over a three year time period to characterize the performance of the instrument and predict the detection limits of future observations. We systematically process images from 359 observations of 304 unique stars to subtract residual starlight (i.e., the coronagraphic point spread function) of the target star using two methods: angular differential imaging (ADI) and reference star differential imaging (RDI). We find that for the typical parallactic angle (PA) rotation of our dataset ($\sim$10$^{\circ}$), RDI provides gains over ADI for angular separations smaller than 0.25$^{\prime\prime}$. Furthermore, we find a power-law relation between the angular separation from the host star and the minimum PA rotation required for ADI to outperform RDI, with a power-law index of -1.18$\pm$0.08. Finally, we use random forest models to estimate ADI and RDI post-processed detection limits a priori. These models, which we provide publicly on a website, explain 70%-80% of the variance in ADI detection limits and 30%-50% of the variance in RDI detection limits. Averaged over a range of angular separations, our models predict both ADI and RDI contrast to within a factor of 2. These results illuminate important factors in high-contrast imaging observations with the NIRC2 vortex coronagraph, help improve observing strategies, and inform future upgrades to the hardware.
△ Less
Submitted 15 August, 2018;
originally announced August 2018.
-
The MICADO first light imager for the ELT: overview, operation, simulation
Authors:
Richard Davies,
João Alves,
Yann Clénet,
Florian Lang-Bardl,
Harald Nicklas,
Jörg-Uwe Pott,
Roberto Ragazzoni,
Eline Tolstoy,
Paola Amico,
Heiko Anwand-Heerwart,
Santiago Barboza,
Lothar Barl,
Pierre Baudoz,
Ralf Bender,
Naidu Bezawada,
Peter Bizenberger,
Wilfried Boland,
Piercarlo Bonifacio,
Bruno Borgo,
Tristan Buey,
Frédéric Chapron,
Fanny Chemla,
Mathieu Cohen,
Oliver Czoske,
Vincent Deo
, et al. (76 additional authors not shown)
Abstract:
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and m…
▽ More
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Hi-5: a potential high-contrast thermal near-infrared imager for the VLTI
Authors:
D. Defrère,
M. Ireland,
O. Absil,
J. -P. Berger,
W. C. Danchi,
S. Ertel,
A. Gallenne,
F. Hénault,
P. Hinz,
E. Huby,
S. Kraus,
L. Labadie,
J. -B. Le Bouquin,
G. Martin,
A. Matter,
B. Mennesson,
A. Mérand,
S. Minardi,
J. D. Monnier,
B. Norris,
G. Orban de Xivry,
E. Pedretti,
J. -U. Pott,
M. Reggiani,
E. Serabyn
, et al. (3 additional authors not shown)
Abstract:
Hi-5 is a high-contrast (or high dynamic range) infrared imager project for the VLTI. Its main goal is to characterize young extra-solar planetary systems and exozodiacal dust around southern main-sequence stars. In this paper, we present an update of the project and key technology pathways to improve the contrast achieved by the VLTI. In particular, we discuss the possibility to use integrated op…
▽ More
Hi-5 is a high-contrast (or high dynamic range) infrared imager project for the VLTI. Its main goal is to characterize young extra-solar planetary systems and exozodiacal dust around southern main-sequence stars. In this paper, we present an update of the project and key technology pathways to improve the contrast achieved by the VLTI. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5~$μ$m) and advanced fringe tracking strategies. We also address the strong exoplanet science case (young exoplanets, planet formation, and exozodiacal disks) offered by this wavelength regime as well as other possible science cases such as stellar physics (fundamental parameters and multiplicity) and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed.
△ Less
Submitted 19 July, 2018;
originally announced July 2018.
-
Review of high-contrast imaging systems for current and future ground-based and space-based telescopes III. Technology opportunities and pathways
Authors:
Frans Snik,
Olivier Absil,
Pierre Baudoz,
Mathilde Beaulieu,
Eduardo Bendek,
Eric Cady,
Brunella Carlomagno,
Alexis Carlotti,
Nick Cvetojevic,
David Doelman,
Kevin Fogarty,
Raphaël Galicher,
Olivier Guyon,
Sebastiaan Haffert,
Elsa Huby,
Jeffrey Jewell,
Nemanja Jovanovic,
Christoph Keller,
Matthew Kenworthy,
Justin Knight,
Jonas Kühnn,
Johan Mazoyer,
Kelsey Miller,
Mamadou N'Diaye,
Barnaby Norris
, et al. (8 additional authors not shown)
Abstract:
The Optimal Optical CoronagraphWorkshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. This contribution is the final part of a series of three papers summarizing the outcomes of the workshop, and presents an overview of novel optical technologies…
▽ More
The Optimal Optical CoronagraphWorkshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. This contribution is the final part of a series of three papers summarizing the outcomes of the workshop, and presents an overview of novel optical technologies and systems that are implemented or considered for high-contrast imaging instruments on both ground-based and space telescopes. The overall objective of high contrast instruments is to provide direct observations and characterizations of exoplanets at contrast levels as extreme as 10^-10. We list shortcomings of current technologies, and identify opportunities and development paths for new technologies that enable quantum leaps in performance. Specifically, we discuss the design and manufacturing of key components like advanced deformable mirrors and coronagraphic optics, and their amalgamation in "adaptive coronagraph" systems. Moreover, we discuss highly integrated system designs that combine contrast-enhancing techniques and characterization techniques (like high-resolution spectroscopy) while minimizing the overall complexity. Finally, we explore extreme implementations using all-photonics solutions for ground-based telescopes and dedicated huge apertures for space telescopes.
△ Less
Submitted 18 July, 2018;
originally announced July 2018.
-
Review of high-contrast imaging systems for current and future ground-based and space-based telescopes II. Common path wavefront sensing/control and Coherent Differential Imaging
Authors:
Nemanja Jovanovic,
Olivier Absil,
Pierre Baudoz,
Mathilde Beaulieu,
Michael Bottom,
Eric Cady,
Brunella Carlomagno,
Alexis Carlotti,
David Doelman,
Kevin Fogarty,
Raphael Galicher,
Olivier Guyon,
Sebastiaan Haffert,
Elsa Huby,
Jeffrey Jewell,
Christoph Keller,
Matthew A. Kenworthy,
Justin Knight,
Jonas Kuhn,
Kelsey Miller,
Johan Mazoyer,
Mamadou N'Diaye,
Emiel Por,
Laurent Pueyo,
A J Eldorado Riggs
, et al. (6 additional authors not shown)
Abstract:
The Optimal Optical Coronagraph (OOC) Workshop held at the Lorentz Center in September 2017 in Leiden, the Netherlands, gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this second installment of a series of three papers summarizing the outcomes of the OOC workshop (see also~\citenum{ruane2018,snik2018}), we pre…
▽ More
The Optimal Optical Coronagraph (OOC) Workshop held at the Lorentz Center in September 2017 in Leiden, the Netherlands, gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this second installment of a series of three papers summarizing the outcomes of the OOC workshop (see also~\citenum{ruane2018,snik2018}), we present an overview of common path wavefront sensing/control and Coherent Differential Imaging techniques, highlight the latest results, and expose their relative strengths and weaknesses. We layout critical milestones for the field with the aim of enhancing future ground/space based high contrast imaging platforms. Techniques like these will help to bridge the daunting contrast gap required to image a terrestrial planet in the zone where it can retain liquid water, in reflected light around a G type star from space.
△ Less
Submitted 18 July, 2018;
originally announced July 2018.
-
Review of high-contrast imaging systems for current and future ground- and space-based telescopes I. Coronagraph design methods and optical performance metrics
Authors:
G. Ruane,
A. Riggs,
J. Mazoyer,
E. H. Por,
M. N'Diaye,
E. Huby,
P. Baudoz,
R. Galicher,
E. Douglas,
J. Knight,
B. Carlomagno,
K. Fogarty,
L. Pueyo,
N. Zimmerman,
O. Absil,
M. Beaulieu,
E. Cady,
A. Carlotti,
D. Doelman,
O. Guyon,
S. Haffert,
J. Jewell,
N. Jovanovic,
C. Keller,
M. A. Kenworthy
, et al. (7 additional authors not shown)
Abstract:
The Optimal Optical Coronagraph (OOC) Workshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this first installment of a series of three papers summarizing the outcomes of the OOC workshop, we present an overview of design methods and optical…
▽ More
The Optimal Optical Coronagraph (OOC) Workshop at the Lorentz Center in September 2017 in Leiden, the Netherlands gathered a diverse group of 25 researchers working on exoplanet instrumentation to stimulate the emergence and sharing of new ideas. In this first installment of a series of three papers summarizing the outcomes of the OOC workshop, we present an overview of design methods and optical performance metrics developed for coronagraph instruments. The design and optimization of coronagraphs for future telescopes has progressed rapidly over the past several years in the context of space mission studies for Exo-C, WFIRST, HabEx, and LUVOIR as well as ground-based telescopes. Design tools have been developed at several institutions to optimize a variety of coronagraph mask types. We aim to give a broad overview of the approaches used, examples of their utility, and provide the optimization tools to the community. Though it is clear that the basic function of coronagraphs is to suppress starlight while maintaining light from off-axis sources, our community lacks a general set of standard performance metrics that apply to both detecting and characterizing exoplanets. The attendees of the OOC workshop agreed that it would benefit our community to clearly define quantities for comparing the performance of coronagraph designs and systems. Therefore, we also present a set of metrics that may be applied to theoretical designs, testbeds, and deployed instruments. We show how these quantities may be used to easily relate the basic properties of the optical instrument to the detection significance of the given point source in the presence of realistic noise.
△ Less
Submitted 18 July, 2018;
originally announced July 2018.
-
High-contrast imaging of HD 163296 with the Keck/NIRC2 L'-band vortex coronograph
Authors:
G. Guidi,
G. Ruane,
J. P. Williams,
D. Mawet,
L. Testi,
A. Zurlo,
O. Absil,
M. Bottom,
E. Choquet,
V. Christiaens,
B. Femenía Castellá,
E. Huby,
A. Isella,
J. Kastner,
T. Meshkat,
M. Reggiani,
A. Riggs,
E. Serabyn,
N. Wallack
Abstract:
We present observations of the nearby (D$\sim$100\,pc) Herbig star HD~163296 taken with the vortex coronograph at Keck/NIRC2 in the L' band (3.7~$μ$m), to search for planetary mass companions in the ringed disc surrounding this pre-main sequence star. The images reveal an arc-like region of scattered light from the disc surface layers that is likely associated with the first bright ring detected w…
▽ More
We present observations of the nearby (D$\sim$100\,pc) Herbig star HD~163296 taken with the vortex coronograph at Keck/NIRC2 in the L' band (3.7~$μ$m), to search for planetary mass companions in the ringed disc surrounding this pre-main sequence star. The images reveal an arc-like region of scattered light from the disc surface layers that is likely associated with the first bright ring detected with ALMA in the $λ$=1.3mm dust continuum at $\sim$65~au. We also detect a point-like source at $\sim$0\farcs5 projected separation in the North-East direction, close to the inner edge of the second gap in the millimetre images. Comparing the point source photometry with the atmospheric emission models of non-accreting giant planets, we obtain a mass of 6--7~M$_J$ for a putative protoplanet, assuming a system age of 5~Myr. Based on the contrast at a 95\% level of completeness calculated on the emission-free regions of our images, we set upper limits for the masses of giant planets of 8--15~M$_J$, 4.5--6.5~M$_J$ and 2.5-4.0~M$_J$ at the locations of the first, second and third gap in the millimetre dust continuum, respectively. Further deep, high resolution thermal IR imaging of the HD~163296 system are warranted, to confirm the presence and nature of the point source and to better understand the structure of the dust disc.
△ Less
Submitted 21 June, 2018;
originally announced June 2018.
-
Design study and first performance simulation of the ELT/MICADO focal plane coronagraphs
Authors:
Clément Perrot,
Pierre Baudoz,
Anthony Boccaletti,
Gérard Rousset,
Elsa Huby,
Yann Clénet,
Sébastien Durand,
Richard Davies
Abstract:
In this paper, we present the design and the expected performance of the classical Lyot coronagraph for the high contrast imaging modes of the wide-field imager MICADO. MICADO is a near-IR camera for the Extremely Large Telescope (ELT, previously E-ELT), with wide-field, spectroscopic and coronagraphic capabilities. MICADO is one of the first-light instruments selected by the ESO. Optimized to wor…
▽ More
In this paper, we present the design and the expected performance of the classical Lyot coronagraph for the high contrast imaging modes of the wide-field imager MICADO. MICADO is a near-IR camera for the Extremely Large Telescope (ELT, previously E-ELT), with wide-field, spectroscopic and coronagraphic capabilities. MICADO is one of the first-light instruments selected by the ESO. Optimized to work with a multi-conjugate adaptive optics corrections provided by the MOARY module, it will also come with a SCAO correction with a high-level, on-axis correction, making use of the M4 adaptive mirror of the telescope.
After presenting the context of the high contrast imaging modes in MICADO, we describe the selection process for the focal plane masks and Lyot stop. We will also show results obtained in realistic conditions, taking into account AO residuals, atmospheric refraction, noise sources and simulating observations in angular differential imaging (ADI) mode. Based on SPHERE on-sky results, we will discuss the achievable gain in contrast and angular separation provided by MICADO over the current instruments on 10-m class telescopes, in particular for imaging young giant planets at very short separations around nearby stars as well as planets on wider orbits around more distant stars in young stellar associations.
△ Less
Submitted 4 April, 2018;
originally announced April 2018.
-
The path towards high-contrast imaging with the VLTI: the Hi-5 project
Authors:
D. Defrère,
O. Absil,
J. -P. Berger,
T. Boulet,
W. C. Danchi,
S. Ertel,
A. Gallenne,
F. Hénault,
P. Hinz,
E. Huby,
M. Ireland,
S. Kraus,
L. Labadie,
J. -B. Le Bouquin,
G. Martin,
A. Matter,
A. Mérand,
B. Mennesson,
S. Minardi,
J. Monnier,
B. Norris,
G. Orban de Xivry,
E. Pedretti,
J. -U. Pott,
M. Reggiani
, et al. (4 additional authors not shown)
Abstract:
The development of high-contrast capabilities has long been recognized as one of the top priorities for the VLTI. As of today, the VLTI routinely achieves contrasts of a few 10$^{-3}$ in the near-infrared with PIONIER (H band) and GRAVITY (K band). Nulling interferometers in the northern hemisphere and non-redundant aperture masking experiments have, however, demonstrated that contrasts of at leas…
▽ More
The development of high-contrast capabilities has long been recognized as one of the top priorities for the VLTI. As of today, the VLTI routinely achieves contrasts of a few 10$^{-3}$ in the near-infrared with PIONIER (H band) and GRAVITY (K band). Nulling interferometers in the northern hemisphere and non-redundant aperture masking experiments have, however, demonstrated that contrasts of at least a few 10$^{-4}$ are within reach using specific beam combination and data acquisition techniques. In this paper, we explore the possibility to reach similar or higher contrasts on the VLTI. After reviewing the state-of-the-art in high-contrast infrared interferometry, we discuss key features that made the success of other high-contrast interferometric instruments (e.g., integrated optics, nulling, closure phase, and statistical data reduction) and address possible avenues to improve the contrast of the VLTI by at least one order of magnitude. In particular, we discuss the possibility to use integrated optics, proven in the near-infrared, in the thermal near-infrared (L and M bands, 3-5 $μ$m), a sweet spot to image and characterize young extra-solar planetary systems. Finally, we address the science cases of a high-contrast VLTI imaging instrument and focus particularly on exoplanet science (young exoplanets, planet formation, and exozodiacal disks), stellar physics (fundamental parameters and multiplicity), and extragalactic astrophysics (active galactic nuclei and fundamental constants). Synergies and scientific preparation for other potential future instruments such as the Planet Formation Imager are also briefly discussed.
△ Less
Submitted 25 May, 2018; v1 submitted 12 January, 2018;
originally announced January 2018.
-
Pioneering high contrast science instruments for planet characterization on giant segmented mirror telescopes
Authors:
N. Jovanovic,
O. Guyon,
J. Lozi,
M. Tamura,
B. Norris,
P. Tuthill,
E. Huby,
G. Perrin,
S. Lacour,
F. Marchis,
G. Duchene,
L. Gauchet,
M. Ireland,
T. Feger,
A. Rains,
J. Bento,
C. Schwab,
D. Coutts,
N. Cvetojevic,
S. Gross,
A. Arriola,
T. Lagadec,
S. Goebel,
D. Hall,
S. Jacobson
, et al. (14 additional authors not shown)
Abstract:
A suite of science instruments is critical to any high contrast imaging facility, as it defines the science capabilities and observing modes available. SCExAO uses a modular approach which allows for state-of-the-art visitor modules to be tested within an observatory environment on an 8-m class telescope. This allows for rapid prototyping of new and innovative imaging techniques that otherwise tak…
▽ More
A suite of science instruments is critical to any high contrast imaging facility, as it defines the science capabilities and observing modes available. SCExAO uses a modular approach which allows for state-of-the-art visitor modules to be tested within an observatory environment on an 8-m class telescope. This allows for rapid prototyping of new and innovative imaging techniques that otherwise take much longer in traditional instrument design. With the aim of maturing science modules for an advanced high contrast imager on an giant segmented mirror telescopes (GSMTs) that will be capable of imaging terrestrial planets, we offer an overview and status update on the various science modules currently under test within the SCExAO instrument.
△ Less
Submitted 22 December, 2017;
originally announced December 2017.
-
Discovery of a point-like source and a third spiral arm in the transition disk around the Herbig Ae star MWC 758
Authors:
M. Reggiani,
V. Christiaens,
O. Absil,
D. Mawet,
E. Huby,
E. Choquet,
C. A. Gomez Gonzalez,
G. Ruane,
B. Femenia,
E. Serabyn,
K. Matthews,
M. Barraza,
B. Carlomagno,
D. Defrère,
C. Delacroix,
S. Habraken,
A. Jolivet,
M. Karlsson,
G. Orban de Xivry,
P. Piron,
J. Surdej,
E. Vargas Catalan,
O. Wertz
Abstract:
Transition disks offer the extraordinary opportunity to look for newly born planets and investigate the early stages of planet formation. In this context we observed the Herbig A5 star MWC 758 with the L band vector vortex coronagraph installed in the near-infrared camera and spectrograph NIRC2 at the Keck II telescope, with the aim of unveiling the nature of the spiral structure by constraining t…
▽ More
Transition disks offer the extraordinary opportunity to look for newly born planets and investigate the early stages of planet formation. In this context we observed the Herbig A5 star MWC 758 with the L band vector vortex coronagraph installed in the near-infrared camera and spectrograph NIRC2 at the Keck II telescope, with the aim of unveiling the nature of the spiral structure by constraining the presence of planetary companions in the system. Our high-contrast imaging observations show a bright (delta L=7.0+/-0.3 mag) point-like emission, south of MWC 758 at a deprojected separation of about 20 au (r=0.111+/- 0. 004 arcsec) from the central star. We also recover the two spiral arms (south-east and north-west), already imaged by previous studies in polarized light, and discover a third one to the south-west of the star. No additional companions were detected in the system down to 5 Jupiter masses beyond 0.6 arcsec from the star. We propose that the bright L band emission could be caused by the presence of an embedded and accreting protoplanet, although the possibility of it being an asymmetric disk feature cannot be excluded. The spiral structure is probably not related to the protoplanet candidate, unless on an inclined and eccentric orbit, and it could be due to one (or more) yet undetected planetary companions at the edge of or outside the spiral pattern. Future observations and additional simulations will be needed to shed light on the true nature of the point-like source and its link with the spiral arms.
△ Less
Submitted 1 December, 2017; v1 submitted 31 October, 2017;
originally announced October 2017.
-
Deep imaging search for planets forming in the TW Hya protoplanetary disk with the Keck/NIRC2 vortex coronagraph
Authors:
G. Ruane,
D. Mawet,
J. Kastner,
T. Meshkat,
M. Bottom,
B. Femenía Castellá,
O. Absil,
C. Gomez Gonzalez,
E. Huby,
Z. Zhu,
R. Jensen-Clem,
É. Choquet,
E. Serabyn
Abstract:
Distinct gap features in the nearest protoplanetary disk, TW Hya (distance of 59.5$\pm$0.9 pc), may be signposts of ongoing planet formation. We performed long-exposure thermal infrared coronagraphic imaging observations to search for accreting planets especially within dust gaps previously detected in scattered light and submm-wave thermal emission. Three nights of observations with the Keck/NIRC…
▽ More
Distinct gap features in the nearest protoplanetary disk, TW Hya (distance of 59.5$\pm$0.9 pc), may be signposts of ongoing planet formation. We performed long-exposure thermal infrared coronagraphic imaging observations to search for accreting planets especially within dust gaps previously detected in scattered light and submm-wave thermal emission. Three nights of observations with the Keck/NIRC2 vortex coronagraph in $L^\prime$ (3.4-4.1$μ$m) did not reveal any statistically significant point sources. We thereby set strict upper limits on the masses of non-accreting planets. In the four most prominent disk gaps at 24, 41, 47, and 88 au, we obtain upper mass limits of 1.6-2.3, 1.1-1.6, 1.1-1.5, and 1.0-1.2 Jupiter masses ($M_J$) assuming an age range of 7-10 Myr for TW Hya. These limits correspond to the contrast at 95\% completeness (true positive fraction of 0.95) with a 1\% chance of a false positive within $1^{\prime\prime}$ of the star. We also approximate an upper limit on the product of planet mass and planetary accretion rate of $M_p\dot{M}\lesssim10^{-8} M_J^2/yr$ implying that any putative $\sim0.1 M_J$ planet, which could be responsible for opening the 24 au gap, is presently accreting at rates insufficient to build up a Jupiter mass within TW Hya's pre-main sequence lifetime.
△ Less
Submitted 20 September, 2018; v1 submitted 22 June, 2017;
originally announced June 2017.
-
On-sky performance of the QACITS pointing control technique with the Keck/NIRC2 vortex coronagraph
Authors:
Elsa Huby,
Michael Bottom,
Bruno Femenia,
Henry Ngo,
Dimitri Mawet,
Eugene Serabyn,
Olivier Absil
Abstract:
A vortex coronagraph is now available for high contrast observations with the Keck/NIRC2 instrument at L band. Reaching the optimal performance of the coronagraph requires fine control of the wavefront incident on the phase mask. In particular, centering errors can lead to significant stellar light leakage that degrades the contrast performance and prevents the observation of faint planetary compa…
▽ More
A vortex coronagraph is now available for high contrast observations with the Keck/NIRC2 instrument at L band. Reaching the optimal performance of the coronagraph requires fine control of the wavefront incident on the phase mask. In particular, centering errors can lead to significant stellar light leakage that degrades the contrast performance and prevents the observation of faint planetary companions around the observed stars. It is thus critical to correct for the possible slow drift of the star image from the phase mask center, generally due to mechanical flexures induced by temperature and/or gravity field variation, or to misalignment between the optics that rotate in pupil tracking mode. A control loop based on the QACITS algorithm for the vortex coronagraph has thus been developed and deployed for the Keck/NIRC2 instrument. This algorithm executes the entire observing sequence, including the calibration steps, initial centering of the star on the vortex center and stabilisation during the acquisition of science frames. On-sky data show that the QACITS control loop stabilizes the position of the star image down to 2.4 mas rms at a frequency of about 0.02 Hz. However, the accuracy of the estimator is probably limited by a systematic error due to a misalignment of the Lyot stop with respect to the entrance pupil, estimated to be on the order of 4.5 mas. A method to reduce the amplitude of this bias down to 1 mas is proposed. The QACITS control loop has been successfully implemented and provides a robust method to center and stabilize the star image on the vortex mask. In addition, QACITS ensures a repeatable pointing quality and significantly improves the observing efficiency compared to manual operations. It is now routinely used for vortex coronagraph observations at Keck/NIRC2, providing contrast and angular resolution capabilities suited for exoplanet and disk imaging.
△ Less
Submitted 23 January, 2017;
originally announced January 2017.
-
The W. M. Keck Observatory infrared vortex coronagraph and a first image of HIP79124 B
Authors:
Eugene Serabyn,
Elsa Huby,
Keith Matthews,
Dimitri Mawet,
Olivier Absil,
Bruno Femenia,
Peter Wizinowich,
Mikael Karlsson,
Michael Bottom,
Randy Campbell,
Brunella Carlomagno,
Denis Defrère,
Christian Delacroix,
Pontus Forsberg,
Carlos Gomez Gonzalez,
Serge Habraken,
Aissa Jolivet,
Kurt Liewer,
Scott Lilley,
Pierre Piron,
Maddalena Reggiani,
Jean Surdej,
Hien Tran,
Ernesto Vargas Catalan,
Olivier Wertz
Abstract:
An optical vortex coronagraph has been implemented within the NIRC2 camera on the Keck II telescope and used to carry out on-sky tests and observations. The development of this new L'-band observational mode is described, and an initial demonstration of the new capability is presented: a resolved image of the low-mass companion to HIP79124, which had previously been detected by means of interferom…
▽ More
An optical vortex coronagraph has been implemented within the NIRC2 camera on the Keck II telescope and used to carry out on-sky tests and observations. The development of this new L'-band observational mode is described, and an initial demonstration of the new capability is presented: a resolved image of the low-mass companion to HIP79124, which had previously been detected by means of interferometry. With HIP79124 B at a projected separation of 186.5 mas, both the small inner working angle of the vortex coronagraph and the related imaging improvements were crucial in imaging this close companion directly. Due to higher Strehl ratios and more relaxed contrasts in L' band versus H band, this new coronagraphic capability will enable high-contrast small-angle observations of nearby young exoplanets and disks on a par with those of shorter-wavelength extreme adaptive optics coronagraphs.
△ Less
Submitted 9 December, 2016;
originally announced December 2016.
-
Characterization of the inner disk around HD 141569 A from Keck/NIRC2 L-band vortex coronagraphy
Authors:
Dimitri Mawet,
Élodie Choquet,
Olivier Absil,
Elsa Huby,
Michael Bottom,
Eugene Serabyn,
Bruno Femenia,
Jérémy Lebreton,
Keith Matthews,
Carlos A. Gomez Gonzalez,
Olivier Wertz,
Brunella Carlomagno,
Valentin Christiaens,
Denis Defrère,
Christian Delacroix,
Pontus Forsberg,
Serge Habraken,
Aissa Jolivet,
Mikael Karlsson,
Julien Milli,
Christophe Pinte,
Pierre Piron,
Maddalena Reggiani,
Jean Surdej,
Ernesto Vargas Catalan
Abstract:
HD 141569 A is a pre-main sequence B9.5 Ve star surrounded by a prominent and complex circumstellar disk, likely still in a transition stage from protoplanetary to debris disk phase. Here, we present a new image of the third inner disk component of HD 141569 A made in the L' band (3.8 micron) during the commissioning of the vector vortex coronagraph recently installed in the near-infrared imager a…
▽ More
HD 141569 A is a pre-main sequence B9.5 Ve star surrounded by a prominent and complex circumstellar disk, likely still in a transition stage from protoplanetary to debris disk phase. Here, we present a new image of the third inner disk component of HD 141569 A made in the L' band (3.8 micron) during the commissioning of the vector vortex coronagraph recently installed in the near-infrared imager and spectrograph NIRC2 behind the W.M. Keck Observatory Keck II adaptive optics system. We used reference point spread function subtraction, which reveals the innermost disk component from the inner working distance of $\simeq 23$ AU and up to $\simeq 70$ AU. The spatial scale of our detection roughly corresponds to the optical and near-infrared scattered light, thermal Q, N and 8.6 micron PAH emission reported earlier. We also see an outward progression in dust location from the L'-band to the H-band (VLT/SPHERE image) to the visible (HST/STIS image), likely indicative of dust blowout. The warm disk component is nested deep inside the two outer belts imaged by HST NICMOS in 1999 (respectively at 406 and 245 AU). We fit our new L'-band image and spectral energy distribution of HD 141569 A with the radiative transfer code MCFOST. Our best-fit models favor pure olivine grains, and are consistent with the composition of the outer belts. While our image shows a putative very-faint point-like clump or source embedded in the inner disk, we did not detect any true companion within the gap between the inner disk and the first outer ring, at a sensitivity of a few Jupiter masses.
△ Less
Submitted 9 December, 2016;
originally announced December 2016.
-
Discovery of a low-mass companion inside the debris ring surrounding the F5V star HD206893
Authors:
Julien Milli,
Pascale Hibon,
Valentin Christiaens,
Elodie Choquet,
Mickael Bonnefoy,
Grant M. Kennedy,
Mark C. Wyatt,
Olivier Absil,
Carlos A. Gomez Gonzalez,
Carlos del Burgo,
Luca Matra,
Jean-Charles Augereau,
Anthony Boccaletti,
Christian Delacroix,
Steve Ertel,
William R. F. Dent,
Pontus Forsberg,
Thierry Fusco,
Julien H. Girard,
Serge Habraken,
Elsa Huby,
Mikael Karlsson,
Anne-Marie Lagrange,
Dimitri Mawet,
David Mouillet
, et al. (8 additional authors not shown)
Abstract:
Uncovering the ingredients and the architecture of planetary systems is a very active field of research that has fuelled many new theories on giant planet formation, migration, composition, and interaction with the circumstellar environment. We aim at discovering and studying new such systems, to further expand our knowledge of how low-mass companions form and evolve. We obtained high-contrast H-b…
▽ More
Uncovering the ingredients and the architecture of planetary systems is a very active field of research that has fuelled many new theories on giant planet formation, migration, composition, and interaction with the circumstellar environment. We aim at discovering and studying new such systems, to further expand our knowledge of how low-mass companions form and evolve. We obtained high-contrast H-band images of the circumstellar environment of the F5V star HD206893, known to host a debris disc never detected in scattered light. These observations are part of the SPHERE High Angular Resolution Debris Disc Survey (SHARDDS) using the InfraRed Dual-band Imager and Spectrograph (IRDIS) installed on VLT/SPHERE. We report the detection of a source with a contrast of 3.6x10^{-5} in the H-band, orbiting at a projected separation of 270 milliarcsecond or 10 au, corresponding to a mass in the range 24 to 73 Mjup for an age of the system in the range 0.2 to 2 Gyr. The detection was confirmed ten months later with VLT/NaCo, ruling out a background object with no proper motion. A faint extended emission compatible with the disc scattered light signal is also observed. The detection of a low-mass companion inside a massive debris disc makes this system an analog of other young planetary systems such as beta Pictoris, HR8799 or HD95086 and requires now further characterisation of both components to understand their interactions.
△ Less
Submitted 6 December, 2016; v1 submitted 1 December, 2016;
originally announced December 2016.
-
Optimizing the subwavelength grating of L-band Annular Groove Phase Masks for high coronagraphic performance
Authors:
Ernesto Vargas Catalan,
Elsa Huby,
Pontus Forsberg,
Aïssa Jolivet,
Pierre Baudoz,
Brunella Carlomagno,
Christian Delacroix,
Serge Habraken,
Dimitri Mawet,
Jean Surdej,
Olivier Absil,
Mikael Karlsson
Abstract:
Context. The Annular Groove Phase Mask (AGPM) is one possible implementation of the vector vortex coronagraph, where the helical phase ramp is produced by a concentric subwavelength grating. For several years, we have been manufacturing AGPMs by etching gratings into synthetic diamond substrates using inductively coupled plasma etching. Aims. We aim to design, fabricate, optimize, and evaluate new…
▽ More
Context. The Annular Groove Phase Mask (AGPM) is one possible implementation of the vector vortex coronagraph, where the helical phase ramp is produced by a concentric subwavelength grating. For several years, we have been manufacturing AGPMs by etching gratings into synthetic diamond substrates using inductively coupled plasma etching. Aims. We aim to design, fabricate, optimize, and evaluate new L-band AGPMs that reach the highest possible coronagraphic performance, for applications in current and forthcoming infrared high-contrast imagers. Methods. Rigorous coupled wave analysis (RCWA) is used for designing the subwavelength grating of the phase mask. Coronagraphic performance evaluation is performed on a dedicated optical test bench. The experimental results of the performance evaluation are then used to accurately determine the actual profile of the fabricated gratings, based on RCWA modeling. Results. The AGPM coronagraphic performance is very sensitive to small errors in etch depth and grating profile. Most of the fabricated components therefore show moderate performance in terms of starlight rejection (a few 100:1 in the best cases). Here we present new processes for re-etching the fabricated components in order to optimize the parameters of the grating and hence significantly increase their coronagraphic performance. Starlight rejection up to 1000:1 is demonstrated in a broadband L filter on the coronagraphic test bench, which corresponds to a raw contrast of about 1e-5 at two resolution elements from the star for a perfect input wave front on a circular, unobstructed aperture. Conclusions. Thanks to their exquisite performance, our latest L-band AGPMs are good candidates for installation in state-of-the-art and future high-contrast thermal infrared imagers, such as METIS for the E-ELT.
△ Less
Submitted 17 October, 2016;
originally announced October 2016.
-
The QACITS pointing sensor: from theory to on-sky operation on Keck/NIRC2
Authors:
Elsa Huby,
Olivier Absil,
Dimitri Mawet,
Pierre Baudoz,
Bruno Femenìa Castellà,
Michael Bottom,
Henry Ngo,
Eugene Serabyn
Abstract:
Small inner working angle coronagraphs are essential to benefit from the full potential of large and future extremely large ground-based telescopes, especially in the context of the detection and characterization of exoplanets. Among existing solutions, the vortex coronagraph stands as one of the most effective and promising solutions. However, for focal-plane coronagraph, a small inner working an…
▽ More
Small inner working angle coronagraphs are essential to benefit from the full potential of large and future extremely large ground-based telescopes, especially in the context of the detection and characterization of exoplanets. Among existing solutions, the vortex coronagraph stands as one of the most effective and promising solutions. However, for focal-plane coronagraph, a small inner working angle comes necessarily at the cost of a high sensitivity to pointing errors. This is the reason why a pointing control system is imperative to stabilize the star on the vortex center against pointing drifts due to mechanical flexures, that generally occur during observation due for instance to temperature and/or gravity variations. We have therefore developed a technique called QACITS (Quadrant Analysis of Coronagraphic Images for Tip-tilt Sensing), which is based on the analysis of the coronagraphic image shape to infer the amount of pointing error. It has been shown that the flux gradient in the image is directly related to the amount of tip-tilt affecting the beam. The main advantage of this technique is that it does not require any additional setup and can thus be easily implemented on all current facilities equipped with a vortex phase mask. In this paper, we focus on the implementation of the QACITS sensor at Keck/NIRC2, where an L-band AGPM has been recently commissioned (June and October 2015), successfully validating the QACITS estimator in the case of a centrally obstructed pupil. The algorithm has been designed to be easily handled by any user observing in vortex mode, which is available for science in shared risk mode since 2016B.
△ Less
Submitted 19 July, 2016;
originally announced July 2016.
-
Three years of harvest with the vector vortex coronagraph in the thermal infrared
Authors:
Olivier Absil,
Dimitri Mawet,
Mikael Karlsson,
Brunella Carlomagno,
Valentin Christiaens,
Denis Defrère,
Christian Delacroix,
Bruno Femenia Castella,
Pontus Forsberg,
Julien Girard,
Carlos A. Gomez Gonzalez,
Serge Habraken,
Philip M. Hinz,
Elsa Huby,
Aïssa Jolivet,
Keith Matthews,
Julien Milli,
Gilles Orban de Xivry,
Eric Pantin,
Pierre Piron,
Maddalena Reggiani,
Garreth J. Ruane,
Eugene Serabyn,
Jean Surdej,
Konrad R. W. Tristram
, et al. (3 additional authors not shown)
Abstract:
For several years, we have been developing vortex phase masks based on sub-wavelength gratings, known as Annular Groove Phase Masks. Etched onto diamond substrates, these AGPMs are currently designed to be used in the thermal infrared (ranging from 3 to 13 μm). Our AGPMs were first installed on VLT/NACO and VLT/VISIR in 2012, followed by LBT/LMIRCam in 2013 and Keck/NIRC2 in 2015. In this paper, w…
▽ More
For several years, we have been developing vortex phase masks based on sub-wavelength gratings, known as Annular Groove Phase Masks. Etched onto diamond substrates, these AGPMs are currently designed to be used in the thermal infrared (ranging from 3 to 13 μm). Our AGPMs were first installed on VLT/NACO and VLT/VISIR in 2012, followed by LBT/LMIRCam in 2013 and Keck/NIRC2 in 2015. In this paper, we review the development, commissioning, on-sky performance, and early scientific results of these new coronagraphic modes and report on the lessons learned. We conclude with perspectives for future developments and applications.
△ Less
Submitted 18 July, 2016;
originally announced July 2016.
-
A Mach-Zehnder interferometer based on orbital angular momentum for improved vortex coronagraph efficiency
Authors:
P. Piron,
C. Delacroix,
E. Huby,
D. Mawet,
M. Karlsson ad G. Ruane,
S. Habraken,
O. Absil,
J. Surdej
Abstract:
The Annular Groove Phase Mask (AGPM) is a vectorial vortex phase mask. It acts as a half-wave plate with a radial fast axis orientation operating in the mid infrared domain. When placed at the focus of a telescope element provides a continuous helical phase ramp for an on axis sources, which creates the orbital angular momentum. Thanks to that phase, the intensity of the central source is canceled…
▽ More
The Annular Groove Phase Mask (AGPM) is a vectorial vortex phase mask. It acts as a half-wave plate with a radial fast axis orientation operating in the mid infrared domain. When placed at the focus of a telescope element provides a continuous helical phase ramp for an on axis sources, which creates the orbital angular momentum. Thanks to that phase, the intensity of the central source is canceled by a down-stream pupil stop, while the off axis sources are not affected. However due to experimental conditions the nulling is hardly perfect. To improve the null, a Mach-Zehnder interferometer containing Dove prisms differently oriented can be proposed to sort out light based on its orbital angular momentum (OAM). Thanks to the differential rotation of the beam, a π phase shift is achieved for the on axis light affected by a non zero OAM. Therefore the contrast between the star and its faint companion is enhanced. Nevertheless, due the Dove prisms birefringence, the performance of the interferometer is relatively poor. To solve this problem, we propose to add a birefringent wave-plate in each arm to compensate this birefringence. In this paper, we will develop the mathematical model of the wave front using the Jones formalism. The performance of the interferometer is at first computed for the simple version without the birefringent plate. Then the effect of the birefringent plate is be mathematically described and the performance is re-computed.
△ Less
Submitted 25 May, 2016;
originally announced May 2016.
-
The VORTEX coronagraphic test bench
Authors:
Aissa Jolivet,
Pierre Piron,
Elsa Huby,
Olivier Absil,
Christian Delacroix,
Dimitri Mawet,
Jean Surdej,
Serge Habraken
Abstract:
In this paper, we present the infrared coronagraphic test bench of the University of Liège named VODCA (Vortex Optical Demonstrator for Coronagraphic Applications). The goal of the bench is to assess the performances of the Annular Groove Phase Masks (AGPMs) at near- to mid-infrared wavelengths. The AGPM is a subwavelength grating vortex coronagraph of charge two (SGVC2) made out of diamond. The b…
▽ More
In this paper, we present the infrared coronagraphic test bench of the University of Liège named VODCA (Vortex Optical Demonstrator for Coronagraphic Applications). The goal of the bench is to assess the performances of the Annular Groove Phase Masks (AGPMs) at near- to mid-infrared wavelengths. The AGPM is a subwavelength grating vortex coronagraph of charge two (SGVC2) made out of diamond. The bench is designed to be completely achromatic and will be composed of a super continuum laser source emitting in the near to mid-infrared, several parabolas, diaphragms and an infrared camera. This way, we will be able to test the different AGPMs in the M, L, K and H bands. Eventually, the bench will also allow the computation of the incident wavefront aberrations on the coronagraph. A reflective Lyot stop will send most of the stellar light to a second camera to perform low-order wavefront sensing. This second system coupled with a deformable mirror will allow the correction of the wavefront aberrations. We also aim to test other pre- and/or post-coronagraphic concepts such as optimal apodization.
△ Less
Submitted 28 April, 2016;
originally announced April 2016.
-
Post-coronagraphic tip-tilt sensing for vortex phase masks: the QACITS technique
Authors:
Elsa Huby,
Pierre Baudoz,
Dimitri Mawet,
Olivier Absil
Abstract:
Small inner working angle coronagraphs, like the vortex phase mask, are essential to exploit the full potential of ground-based telescopes in the context of exoplanet detection and characterization. However, the drawback of this attractive feature is a high sensitivity to pointing errors, which degrades the performance of the coronagraph. We propose a tip-tilt retrieval technique based on the anal…
▽ More
Small inner working angle coronagraphs, like the vortex phase mask, are essential to exploit the full potential of ground-based telescopes in the context of exoplanet detection and characterization. However, the drawback of this attractive feature is a high sensitivity to pointing errors, which degrades the performance of the coronagraph. We propose a tip-tilt retrieval technique based on the analysis of the final coronagraphic image, hereafter called Quadrant Analysis of Coronagraphic Images for Tip-tilt Sensing (QACITS). Under the assumption of small phase aberrations, we show that the behaviour of the vortex phase mask can be simply described from the entrance pupil to the Lyot stop plane by Zernike polynomials. This convenient formalism is used to establish the theoretical basis of the QACITS technique. Simulations have been performed to demonstrate the validity and limits of the technique, including the case of a centrally obstructed pupil. The QACITS technique principle is further validated by experimental results in the case of an unobstructed circular aperture. The typical configuration of the Keck telescope (24% central obstruction) has been simulated with additional high order aberrations. In these conditions, our simulations show that the QACITS technique is still adapted to centrally obstructed pupils and performs tip-tilt retrieval with a precision of $5 \times 10^{-2}$ λ/D when wavefront errors amount to λ/14 rms and $10^{-2}$ λ/D for λ/70 rms errors (with λ the wavelength and D the pupil diameter). The implementation of the QACITS technique is based on the analysis of the scientific image and does not require any modification of the original setup. Current facilities equipped with a vortex phase mask can thus directly benefit from this technique to improve the contrast performance close to the axis.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Optimized focal and pupil plane masks for vortex coronagraphs on telescopes with obstructed apertures
Authors:
Garreth J. Ruane,
Olivier Absil,
Elsa Huby,
Dimitri Mawet,
Christian Delacroix,
Brunella Carlomagno,
Pierre Piron,
Grover A. Swartzlander Jr
Abstract:
We present methods for optimizing pupil and focal plane optical elements that improve the performance of vortex coronagraphs on telescopes with obstructed or segmented apertures. Phase-only and complex masks are designed for the entrance pupil, focal plane, and the plane of the Lyot stop. Optimal masks are obtained using both analytical and numerical methods. The latter makes use of an iterative e…
▽ More
We present methods for optimizing pupil and focal plane optical elements that improve the performance of vortex coronagraphs on telescopes with obstructed or segmented apertures. Phase-only and complex masks are designed for the entrance pupil, focal plane, and the plane of the Lyot stop. Optimal masks are obtained using both analytical and numerical methods. The latter makes use of an iterative error reduction algorithm to calculate "correcting" optics that mitigate unwanted diffraction from aperture obstructions. We analyze the achieved performance in terms of starlight suppression, contrast, off-axis image quality, and chromatic dependence. Manufacturing considerations and sensitivity to aberrations are also discussed. This work provides a path to joint optimization of multiple coronagraph planes to maximize sensitivity to exoplanets and other faint companions.
△ Less
Submitted 18 September, 2015;
originally announced September 2015.
-
Lyot-plane phase masks for improved high-contrast imaging with a vortex coronagraph
Authors:
Garreth J. Ruane,
Elsa Huby,
Olivier Absil,
Dimitri Mawet,
Christian Delacroix,
Brunella Carlomagno,
Grover A. Swartzlander
Abstract:
The vortex coronagraph is an optical instrument that precisely removes on-axis starlight allowing for high contrast imaging at small angular separation from the star, thereby providing a crucial capability for direct detection and characterization of exoplanets and circumstellar disks. Telescopes with aperture obstructions, such as secondary mirrors and spider support structures, require advanced…
▽ More
The vortex coronagraph is an optical instrument that precisely removes on-axis starlight allowing for high contrast imaging at small angular separation from the star, thereby providing a crucial capability for direct detection and characterization of exoplanets and circumstellar disks. Telescopes with aperture obstructions, such as secondary mirrors and spider support structures, require advanced coronagraph designs to provide adequate starlight suppression. We introduce a phase-only Lyot-plane optic to the vortex coronagraph that offers improved contrast performance on telescopes with complicated apertures. Potential solutions for the European Extremely Large Telescope (E-ELT) are described and compared. Adding a Lyot-plane phase mask relocates residual starlight away from a region of the image plane thereby reducing stellar noise and improving sensitivity to off-axis companions. The phase mask is calculated using an iterative phase retrieval algorithm. Numerically, we achieve a contrast on the order of $10^{-6}$ for a companion with angular displacement as small as $4~λ/D$ with an E-ELT type aperture. Even in the presence of aberrations, improved performance is expected compared to either a conventional vortex coronagraph or optimized pupil plane phase element alone.
△ Less
Submitted 18 September, 2015;
originally announced September 2015.
-
The Subaru Coronagraphic Extreme Adaptive Optics system: enabling high-contrast imaging on solar-system scales
Authors:
N. Jovanovic,
F. Martinache,
O. Guyon,
C. Clergeon,
G. Singh,
T. Kudo,
V. Garrel,
K. Newman,
D. Doughty,
J. Lozi,
J. Males,
Y. Minowa,
Y. Hayano,
N. Takato,
J. Morino,
J. Kuhn,
E. Serabyn,
B. Norris,
P. Tuthill,
G. Schworer,
P. Stewart,
L. Close,
E. Huby,
G. Perrin,
S. Lacour
, et al. (13 additional authors not shown)
Abstract:
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is a multipurpose high-contrast imaging platform designed for the discovery and detailed characterization of exoplanetary systems and serves as a testbed for high-contrast imaging technologies for ELTs. It is a multi-band instrument which makes use of light from 600 to 2500nm allowing for coronagraphic direct exoplanet imaging of…
▽ More
The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument is a multipurpose high-contrast imaging platform designed for the discovery and detailed characterization of exoplanetary systems and serves as a testbed for high-contrast imaging technologies for ELTs. It is a multi-band instrument which makes use of light from 600 to 2500nm allowing for coronagraphic direct exoplanet imaging of the inner 3 lambda/D from the stellar host. Wavefront sensing and control are key to the operation of SCExAO. A partial correction of low-order modes is provided by Subaru's facility adaptive optics system with the final correction, including high-order modes, implemented downstream by a combination of a visible pyramid wavefront sensor and a 2000-element deformable mirror. The well corrected NIR (y-K bands) wavefronts can then be injected into any of the available coronagraphs, including but not limited to the phase induced amplitude apodization and the vector vortex coronagraphs, both of which offer an inner working angle as low as 1 lambda/D. Non-common path, low-order aberrations are sensed with a coronagraphic low-order wavefront sensor in the infrared (IR). Low noise, high frame rate, NIR detectors allow for active speckle nulling and coherent differential imaging, while the HAWAII 2RG detector in the HiCIAO imager and/or the CHARIS integral field spectrograph (from mid 2016) can take deeper exposures and/or perform angular, spectral and polarimetric differential imaging. Science in the visible is provided by two interferometric modules: VAMPIRES and FIRST, which enable sub-diffraction limited imaging in the visible region with polarimetric and spectroscopic capabilities respectively. We describe the instrument in detail and present preliminary results both on-sky and in the laboratory.
△ Less
Submitted 30 June, 2015;
originally announced July 2015.
-
The VORTEX project: first results and perspectives
Authors:
Olivier Absil,
Dimitri Mawet,
Christian Delacroix,
Pontus Forsberg,
Mikael Karlsson,
Serge Habraken,
Jean Surdej,
Pierre-Antoine Absil,
Brunella Carlomagno,
Valentin Christiaens,
Denis Defrere,
Carlos Gomez Gonzalez,
Elsa Huby,
Aissa Jolivet,
Julien Milli,
Pierre Piron,
Ernesto Vargas Catalan,
Marc Van Droogenbroeck
Abstract:
(abridged) Vortex coronagraphs are among the most promising solutions to perform high contrast imaging at small angular separations. They feature a very small inner working angle, a clear 360 degree discovery space, have demonstrated very high contrast capabilities, are easy to implement on high-contrast imaging instruments, and have already been extensively tested on the sky. Since 2005, we have…
▽ More
(abridged) Vortex coronagraphs are among the most promising solutions to perform high contrast imaging at small angular separations. They feature a very small inner working angle, a clear 360 degree discovery space, have demonstrated very high contrast capabilities, are easy to implement on high-contrast imaging instruments, and have already been extensively tested on the sky. Since 2005, we have been designing, developing and testing an implementation of the charge-2 vector vortex phase mask based on concentric subwavelength gratings, referred to as the Annular Groove Phase Mask (AGPM). Science-grade mid-infrared AGPMs were produced in 2012 for the first time, using plasma etching on synthetic diamond substrates. They have been validated on a coronagraphic test bench, showing broadband peak rejection up to 500:1 in the L band, which translates into a raw contrast of about $6\times 10^{-5}$ at $2 λ/D$. Three of them have now been installed on world-leading diffraction-limited infrared cameras (VLT/NACO, VLT/VISIR and LBT/LMIRCam). During the science verification observations with our L-band AGPM on NACO, we observed the beta Pictoris system and obtained unprecedented sensitivity limits to planetary companions down to the diffraction limit ($0.1''$). More recently, we obtained new images of the HR 8799 system at L band during the AGPM first light on LMIRCam. After reviewing these first results obtained with mid-infrared AGPMs, we will discuss the short- and mid-term goals of the on-going VORTEX project, which aims to improve the performance of our vortex phase masks for future applications on second-generation high-contrast imagers and on future extremely large telescopes (ELTs).
△ Less
Submitted 21 October, 2014;
originally announced October 2014.