MKIDGen3: Energy-Resolving, Single-Photon-Counting MKID Readout on an RFSoC
Authors:
Jennifer Pearl Smith,
John I. Bailey,
III.,
Aled Cuda,
Nicholas Zobrist,
Benjamin A. Mazin
Abstract:
Building large, cryogenic MKID arrays requires processing highly-multiplexed, wideband readout signals in real time; a task that has previously required large, heavy, and power-intensive custom electronics. In this work, we present the third-generation UVOIR MKID readout system (Gen3) which is capable of reading out twice as many detectors with a fifth the weight and power and an order of magnitud…
▽ More
Building large, cryogenic MKID arrays requires processing highly-multiplexed, wideband readout signals in real time; a task that has previously required large, heavy, and power-intensive custom electronics. In this work, we present the third-generation UVOIR MKID readout system (Gen3) which is capable of reading out twice as many detectors with a fifth the weight and power and an order of magnitude less volume and cost-per-pixel as compared to the previous system. Gen3 leverages the Xilinx RFSoC4x2 platform to read out 2048, 1 MHz MKID channels per board. The system takes a modern approach to FPGA design using Vitis High-Level Synthesis (HLS) to specify signal processing blocks in C/C++, Vivado ML Intelligent Design Runs (IDR) to inform implementation stragety and close timing, and Python Productivity for ZYNQ (PYNQ) to simplify interacting with and programming the FPGA using Python. This design suite and tool flow allows general users to contribute to and maintain the design and positions Gen3 to rapidly migrate to future platforms as they become available. In this work, we describe the system requirements, design, and implementation. We also provide performance characterization details and show that the system achieves detector-limited resolving power in the case of few readout tones and minimal degradation with all 2048 tones. Planned upgrades and future work are also discussed. The Gen3 MKID readout system is fully open-source and is expected to facilitate future array scaling to megapixel-sized formats and increase the feasibility of deploying UVOIR MKIDs in space.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Characterizing the Dark Count Rate of a Large-Format MKID Array
Authors:
Noah Swimmer,
W. Hawkins Clay,
Nicholas Zobrist,
Benjamin A. Mazin
Abstract:
We present an empirical measurement of the dark count rate seen in a large-format MKID array identical to those currently in use at observatories such as Subaru on Maunakea. This work provides compelling evidence for their utility in future experiments that require low-count rate, quiet environments such as dark matter direct detection. Across the bandpass from 0.946-1.534 eV (1310-808 nm) an aver…
▽ More
We present an empirical measurement of the dark count rate seen in a large-format MKID array identical to those currently in use at observatories such as Subaru on Maunakea. This work provides compelling evidence for their utility in future experiments that require low-count rate, quiet environments such as dark matter direct detection. Across the bandpass from 0.946-1.534 eV (1310-808 nm) an average count rate of $(1.847\pm0.003)\times10^{-3}$ photons/pixel/s is measured. Breaking this bandpass into 5 equal-energy bins based on the resolving power of the detectors we find the average dark count rate seen in an MKID is $(6.26\pm0.04)\times10^{-4}$ photons/pixel/s from 0.946-1.063 eV and $(2.73\pm0.02)\times10^{-4}$ photons/pixel/s at 1.416-1.534eV. Using lower-noise readout electronics to read out a single MKID pixel we demonstrate that the events measured while the detector is not illuminated largely appear to be a combination of real photons, possible fluorescence caused by cosmic rays, and phonon events in the array substrate. We also find that using lower-noise readout electronics on a single MKID pixel we measure a dark count rate of $(9.3\pm0.9)\times10^{-4}$ photons/pixel/s over the same bandpass (0.946-1.534 eV) With the single-pixel readout we also characterize the events when the detectors are not illuminated and show that these responses in the MKID are distinct from photons from known light sources such as a laser, likely coming from cosmic ray excitations.
△ Less
Submitted 7 February, 2023;
originally announced February 2023.
-
SCExAO and Keck Direct Imaging Discovery of a Low-Mass Companion Around the Accelerating F5 Star HIP 5319
Authors:
Noah Swimmer,
Thayne Currie,
Sarah Steiger,
Gregory Mirek Brandt,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Taylor Tobin,
Tyler D. Groff,
Julien Lozi,
John I. Bailey III,
Alexander B. Walter,
Neelay Fruitwala,
Nicholas Zobrist,
Jennifer Pearl Smith,
Gregoire Coiffard,
Rupert Dodkins,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Nour Skaf,
Vincent Deo,
Nemanja Jovanovic
, et al. (4 additional authors not shown)
Abstract:
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of…
▽ More
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of T=3200 K and surface gravity log($g$)=5.5. Using the relative astrometry for HIP 5319 B from CHARIS and NIRC2 and absolute astrometry for the primary from $Gaia$ and $Hipparcos$ and adopting a log-normal prior assumption for the companion mass, we measure a dynamical mass for HIP 5319 B of $31^{+35}_{-11}M_{\rm J}$, a semimajor axis of $18.6^{+10}_{-4.1}$ au, an inclination of $69.4^{+5.6}_{-15}$ degrees, and an eccentricity of $0.42^{+0.39}_{-0.29}$. However, using an alternate prior for our dynamical model yields a much higher mass of 128$^{+127}_{-88}M_{\rm J}$. Using data taken with the LCOGT NRES instrument we also show that the primary HIP 5319 A is a single star in contrast to previous characterizations of the system as a spectroscopic binary. This work underscores the importance of assumed priors in dynamical models for companions detected with imaging and astrometry and the need to have an updated inventory of system measurements.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
Membrane-less phonon trapping and resolution enhancement in optical microwave kinetic inductance detectors
Authors:
Nicholas Zobrist,
W. Hawkins Clay,
Grégoire Coiffard,
Miguel Daal,
Noah Swimmer,
Peter Day,
Benjamin A. Mazin
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) sensitive to light in the ultraviolet to near-infrared wavelengths are superconducting micro-resonators that are capable of measuring photon arrival times to microsecond precision and estimating each photon's energy. The resolving power of non-membrane MKIDs has remained stubbornly around 10 at 1 $μ$m despite significant improvements in the system noi…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) sensitive to light in the ultraviolet to near-infrared wavelengths are superconducting micro-resonators that are capable of measuring photon arrival times to microsecond precision and estimating each photon's energy. The resolving power of non-membrane MKIDs has remained stubbornly around 10 at 1 $μ$m despite significant improvements in the system noise. Here we show that the resolving power can be roughly doubled with a simple bilayer design without needing to place the device on a membrane, avoiding a significant increase in fabrication complexity. Based on modeling of the phonon propagation, we find that the majority of the improvement comes from the inability of high energy phonons to enter the additional layer due to the lack of available phonon states.
△ Less
Submitted 28 April, 2022;
originally announced April 2022.
-
The MKID Science Data Pipeline
Authors:
Sarah Steiger,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Rupert Dodkins,
Kristina K. Davis,
Benjamin A. Mazin
Abstract:
We present The MKID Pipeline, a general use science data pipeline for the reduction and analysis of ultraviolet, optical and infrared (UVOIR) Microwave Kinetic Inductance Detector (MKID) data sets. This paper provides an introduction to the nature of MKID data sets, an overview of the calibration steps included in the pipeline, and an introduction to the implementation of the software.
We present The MKID Pipeline, a general use science data pipeline for the reduction and analysis of ultraviolet, optical and infrared (UVOIR) Microwave Kinetic Inductance Detector (MKID) data sets. This paper provides an introduction to the nature of MKID data sets, an overview of the calibration steps included in the pipeline, and an introduction to the implementation of the software.
△ Less
Submitted 2 March, 2022;
originally announced March 2022.
-
Improving the energy resolution of photon counting Microwave Kinetic Inductance Detectors using principal component analysis
Authors:
Jacob M. Miller,
Nicholas Zobrist,
Gerhard Ulbricht,
Benjamin A. Mazin
Abstract:
We develop a photon energy measurement scheme for single photon counting Microwave Kinetic Inductance Detectors (MKIDs) that uses principal component analysis (PCA) to measure the energy of an incident photon from the signal ("photon pulse") generated by the detector. PCA can be used to characterize a photon pulse using an arbitrarily large number of features and therefore PCA-based energy measure…
▽ More
We develop a photon energy measurement scheme for single photon counting Microwave Kinetic Inductance Detectors (MKIDs) that uses principal component analysis (PCA) to measure the energy of an incident photon from the signal ("photon pulse") generated by the detector. PCA can be used to characterize a photon pulse using an arbitrarily large number of features and therefore PCA-based energy measurement does not rely on the assumption of an energy-independent pulse shape that is made in standard filtering techniques. A PCA-based method for energy measurement is especially useful in applications where the detector is operating near its saturation energy and pulse shape varies strongly with photon energy. It has been shown previously that PCA using two principal components can be used as an energy-measurement scheme. We extend upon these ideas and develop a method for measuring the energies of photons by characterizing their pulse shapes using any number of principal components and any number of calibration energies. Applying this technique with 50 principal components, we show improvements to a previously-reported energy resolution for Thermal Kinetic Inductance Detectors (TKIDs) from 75 eV to 43 eV at 5.9 keV. We also apply this technique with 50 principal components to data from an optical to near-IR MKID and achieve energy resolutions that are consistent with the best results from existing analysis techniques.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
SCExAO/MEC and CHARIS Discovery of a Low Mass, 6 AU-Separation Companion to HIP 109427 using Stochastic Speckle Discrimination and High-Contrast Spectroscopy
Authors:
Sarah Steiger,
Thayne Currie,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Tyler D. Groff,
Julien Lozi,
Alexander B. Walter,
Neelay Fruitwala,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Clint Bockstiegel,
Seth R. Meeker,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Ananya Sahoo
, et al. (6 additional authors not shown)
Abstract:
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band a…
▽ More
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up $L_{\rm p}$ photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4-M5.5, 3000-3200 $K$, and $\log_{10}(L/L_{\rm \odot}) = -2.28^{+0.04}_{-0.04}$, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia-Hipparcos absolute astrometry of the primary favor a semimajor axis of $6.55^{+3.0}_{-0.48}$ au, an eccentricity of $0.54^{+0.28}_{-0.15}$, an inclination of $66.7^{+8.5}_{-14}$ degrees, and a dynamical mass of $0.280^{+0.18}_{-0.059}$ $M_{\odot}$. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely-used post-processing methods to directly image faint companions to nearby stars near the telescope diffraction limit.
△ Less
Submitted 12 July, 2021; v1 submitted 11 March, 2021;
originally announced March 2021.
-
Improving the dynamic range of single photon counting kinetic inductance detectors
Authors:
Nicholas Zobrist,
Nikita Klimovich,
Byeong Ho Eom,
Grégoire Coiffard,
Miguel Daal,
Noah Swimmer,
Sarah Steiger,
Bruce Bumble,
Henry G. LeDuc,
Peter Day,
Benjamin A. Mazin
Abstract:
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the c…
▽ More
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the coordinate nonlinearity is primarily responsible for limiting its resolving power, this technique leads to increased dynamic range, which we show by applying the transformation to data from a hafnium MKID designed to be sensitive to photons with wavelengths in the 800 to 1300 nm range. The new coordinates allow the detector to resolve photons with wavelengths down to 400 nm, raising the resolving power at that wavelength from 6.8 to 17.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors
Authors:
Neelay Fruitwala,
Paschal Strader,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Chris Stoughton,
Alex B. Walter,
Nicholas Zobrist,
Giulia Collura,
Isabel Lipartito,
John I. Bailey III,
Benjamin A. Mazin
Abstract:
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of r…
▽ More
We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core signal processing architecture from the first generation system, but with a significantly higher bandwidth, enabling readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 -- 8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below -30 dBc.
△ Less
Submitted 12 November, 2020;
originally announced November 2020.
-
The MKID Exoplanet Camera for Subaru SCExAO
Authors:
Alexander B. Walter,
Neelay Fruitwala,
Sarah Steiger,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Seth R. Meeker,
Clint Bockstiegel,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Giulia Collura,
Olivier Guyon,
Julien Lozi,
Sebastien Vievard,
Nemanja Jovanovic,
Frantz Martinache,
Thayne Currie,
Benjamin A. Mazin
Abstract:
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument a…
▽ More
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$λ/ D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.
-
Flexible Coaxial Ribbon Cable for High-Density Superconducting Microwave Device Arrays
Authors:
Jennifer Pearl Smith,
Benjamin A. Mazin,
Alex B. Walter,
Miguel Daal,
J. I. Bailey, III,
Clinton Bockstiegel,
Nicholas Zobrist,
Noah Swimmer,
Sarah Steiger,
Neelay Fruitwala
Abstract:
Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA…
▽ More
Superconducting electronics often require high-density microwave interconnects capable of transporting signals between temperature stages with minimal loss, cross talk, and heat conduction. We report the design and fabrication of superconducting 53 wt% Nb-47 wt% Ti (Nb47Ti) FLexible coAXial ribbon cables (FLAX). The ten traces each consist of a 0.076 mm O.D. NbTi inner conductor insulated with PFA (0.28 mm O.D.) and sheathed in a shared 0.025 mm thick Nb47Ti outer conductor. The cable is terminated with G3PO coaxial push-on connectors via stainless steel capillary tubing (1.6 mm O.D., 0.13 mm thick) soldered to a coplanar wave guide transition board. The 30 cm long cable has 1 dB of loss at 8 GHz with -60 dB nearest-neighbor forward cross talk. The loss is 0.5 dB more than commercially available superconducting coax likely due to impedance mismatches caused by manufacturing imperfections in the cable. The reported cross talk is 30 dB lower than previously developed laminated NbTi-onKapton microstrip cables. We estimate the heat load from 1 K to 90 mK to be 20 nW per trace, approximately half the computed load from the smallest commercially available superconducting coax from CryoCoax
△ Less
Submitted 13 July, 2020;
originally announced July 2020.
-
Characterization of sputtered hafnium thin films for high quality factor microwave kinetic inductance detectors
Authors:
G. Coiffard,
M. Daal,
N. Zobrist,
N. Swimmer,
S. Steiger,
B. Bumble,
B. A. Mazin
Abstract:
Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 μΩ. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, w…
▽ More
Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 μΩ. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, we study how sputter conditions and especially the power applied to the target during the deposition, affect the hafnium $T_{C}$, resistivity, stress, texture and preferred crystal orientation. We find that the position of the target with respect to the substrate strongly affects the orientation of the crystallites in the films and the internal quality factor, $Q_{i}$, of MKIDs fabricated from the films. In particular, we demonstrate that a DC magnetron sputter deposition at a normal angle of incidence, low pressure, and low plasma power promotes the growth of compressive (002)-oriented films and that such films can be used to make high quality factor MKIDs with $Q_{i}$ up to 600,000.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
Authors:
Nicholas Zobrist,
Grégoire Coiffard,
Bruce Bumble,
Noah Swimmer,
Sarah Steiger,
Miguel Daal,
Giulia Collura,
Alex B. Walter,
Clint Bockstiegel,
Neelay Fruitwala,
Isabel Lipartito,
Benjamin A. Mazin
Abstract:
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $μΩ$ cm with an RRR = 1.6. Resonators on the device displayed internal quality fa…
▽ More
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $μΩ$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $μ$s and resolving powers of ~9 at 800 nm.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s
Authors:
Benjamin A. Mazin,
Jeb Bailey,
Jo Bartlett,
Clint Bockstiegel,
Bruce Bumble,
Gregoire Coiffard,
Thayne Currie,
Miguel Daal,
Kristina Davis,
Rupert Dodkins,
Neelay Fruitwala,
Nemanja Jovanovic,
Isabel Lipartito,
Julien Lozi,
Jared Males,
Dimitri Mawet,
Seth Meeker,
Kieran O'Brien,
Michael Rich,
Jenny Smith,
Sarah Steiger,
Noah Swimmer,
Alex Walter,
Nick Zobrist,
Jonas Zmuidzinas
Abstract:
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.
-
Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
Authors:
Nicholas Zobrist,
Byeong Ho Eom,
Peter Day,
Benjamin A. Mazin,
Seth R. Meeker,
Bruce Bumble,
Henry G. LeDuc,
Gérgoire Coiffard,
Paul Szypryt,
Neelay Fruitwala,
Isabel Lipartito,
Clint Bockstiegel
Abstract:
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based trav…
▽ More
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
Properties of selected structural and flat flexible cabling materials for low temperature applications
Authors:
M. Daal,
N. Zobrist,
N. Kellaris,
B. Sadoulet,
M. Robertson
Abstract:
We present measurements of the low temperature thermal conductivity for materials useful in the construction of cryogenic supports for scientific instrumentation and in the fabrication of flat flexible cryogenic cabling. The materials we measure have relatively low thermal conductivity. We present a method for measuring the heat transfer coefficient of flat cabling and show, using an example, that…
▽ More
We present measurements of the low temperature thermal conductivity for materials useful in the construction of cryogenic supports for scientific instrumentation and in the fabrication of flat flexible cryogenic cabling. The materials we measure have relatively low thermal conductivity. We present a method for measuring the heat transfer coefficient of flat cabling and show, using an example, that the thermal conductivity of a flex cable is reasonably well predicted by composing the thermal conductivities of its constituent material layers. Room temperature physical and mechanical data is given for the materials studied, as well as an overview of relevant materials science and manufacturing details. Materials include Timet Ti 15-3 and Ti 21S, Materion alloy vit105 (LM105) in amorphous state, ATI Metals Nb-47Ti, Johnson Matthey nitinol (NiTi), Mersen graphite grade 2020, DuPont Pyralux coverlay and Vespel SCP-5050, and Fralock Cirlex polyimide sheets. All data is in the temperature range 0.5 to 2 K, and up to 5 K for SCP-5050.
△ Less
Submitted 10 January, 2019; v1 submitted 24 October, 2018;
originally announced October 2018.
-
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Authors:
Seth R. Meeker,
Benjamin A. Mazin,
Alex B. Walter,
Paschal Strader,
Neelay Fruitwala,
Clint Bockstiegel,
Paul Szypryt,
Gerhard Ulbricht,
Gregoire Coiffard,
Bruce Bumble,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Giulia Collura,
Rupert Dodkins,
Isabel Lipartito,
Nicholas Zobrist,
Michael Bottom,
J. Chris Shelton,
Dimitri Mawet,
Julian C. van Eyken,
Gautam Vasisht,
Eugene Serabyn
Abstract:
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques an…
▽ More
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
△ Less
Submitted 16 April, 2018; v1 submitted 28 March, 2018;
originally announced March 2018.
-
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
Authors:
P. Szypryt,
S. R. Meeker,
G. Coiffard,
N. Fruitwala,
B. Bumble,
G. Ulbricht,
A. B. Walter,
M. Daal,
C. Bockstiegel,
G. Collura,
N. Zobrist,
I. Lipartito,
B. A. Mazin
Abstract:
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical…
▽ More
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.
△ Less
Submitted 19 October, 2017;
originally announced October 2017.